Photoelectric Sensors: RT-610 Specifications

  • Sales
  • Support
  • Product Catalog
  • Trial/Sample Unit
  • Downloads
Type U-shaped thru-beam
Model No. RT-610-10 RT-610-20 RT-610-50
Sensing range (fixed) 10 mm 0.394 in 20 mm 0.787 in 50 mm 1.969 in
Sensing object ø4 mm ø0.157 in or more opaque object
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption 40 mA or less
Output NPN transistor universal
・Maximum sink current: 80 mA
・Residual voltage: 1 V or less (at 80 mA sink current)
Utilization category DC-12 or DC-13 - DC-12 or DC-13
Output operation Incorporated with two outputs, Light-ON / Dark-ON
Response time 0.1 ms or less 1 ms or less 0.1 ms or less
Operation indicator Red LED (lights up under light received condition)
Sensitivity adjuster Continuously variable adjuster -
Pollution degree 3 (Industrial environment) - 3 (Industrial environment)
Protection IP62 (IEC) IP66 (IEC)
Ambient temperature -10 to +60 °C +14 to +140 °F
(No dew condensation or icing allowed),
Storage: -10 to +60 °C +14 to +140 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,500 lx (RT-610-20R/20G: 1,000 lx) at the light-receiving face
EMC EN 60947-5-2 - EN 60947-5-2
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Emitting element Infrared LED (modulated)
Peak emission wavelength 950 nm
0.037 mil
940 nm
0.037 mil
950 nm
0.037 mil
Enclosure earthing
Floating Capacitor earth Floating
Material Enclosure: Die-cast aluminum
Cable 0.3 mm2 4-core cabtyre cable, 1 m 3.281 ft long (RT-610-20, RT-610-20R and RT-610-20G: 2 m 6.562 ft long)
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight 150 g approx. 240 g approx. 180 g approx.
Accessories Adjusting screwdriver: 1 pc. (Accessory for RT-610-20), Insulation fitting: 1 set (Accessory for RT-610-20)

^ Back to top

Type U-shaped thru-beam
For mark sensing
Model No. RT-610
-10R
RT-610
-20R
RT-610
-10G
RT-610
-20G
Sensing range (fixed) 10 mm 0.394 in 20 mm 0.787 in 10 mm 0.394 in 20 mm 0.787 in
Sensing object ø4 mm ø0.157 in or more opaque or translucent object (Note 2)
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption 40 mA or less
Output NPN transistor universal
・Maximum sink current: 80 mA
・Residual voltage: 1 V or less (at 80 mA sink current)
Utilization category DC-12 or DC-13 -
Output operation Incorporated with two outputs, Light-ON / Dark-ON
Response time 0.1 ms or less 1 ms or less 0.1 ms or less 1 ms or less
Operation indicator Red LED (lights up under light received condition)
Sensitivity adjuster Continuously variable adjuster
Pollution degree 3 (Industrial environment) -
Protection IP62 (IEC) IP66 (IEC) IP62 (IEC) IP66 (IEC)
Ambient temperature -10 to +60 °C +14 to +140 °F
(No dew condensation or icing allowed),
Storage: -10 to +60 °C +14 to +140 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,500 lx (RT-610-20R/20G: 1,000 lx) at the light-receiving face
EMC EN 60947-5-2 -
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Emitting element Red LED (modulated) Green LED (modulated)
Peak emission wavelength 680 nm 0.027 mil 570 nm 0.022 mil
Enclosure earthing
Floating Capacitor earth Floating Capacitor earth
Material Enclosure: Die-cast aluminum
Cable 0.3 mm2 4-core cabtyre cable, 1 m 3.281 ft long
(RT-610-20, RT-610-20R and RT-610-20G: 2 m 6.562 ft long)
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight 150 g approx. 240 g approx. 150 g approx. 240 g approx.
Accessories Adjusting screwdriver: 1 pc. (Accessory for RT-610-20), Insulation fitting: 1 set (Accessory for RT-610-20)

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F .
2) Make sure to confirm detection with an actual sensor before use.

^ Back to top