Area Sensors: NA2-N Specifications

Number of beam channels 8 12 16
Model No. NPN output NA2-N8 NA2-N12 NA2-N16
PNP output NA2-N8-PN NA2-N12-PN NA2-N16-PN
Sensing height 140 mm 5.512 in 220 mm 8.661 in 300 mm 11.811 in
Sensing range 5 m 16.404 ft
Beam pitch 20 mm 0.787 in
Sensing object ø30 mm ø1.181 in or more opaque object
(completely beam interrupted objects)
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Power consumption (Note 2) Emitter Job indicator ON 0.7 W or less 0.8 W or less 0.9 W or less
Job indicator OFF 0.6 W or less 0.7 W or less 0.8 W or less
Receiver Job indicator ON 0.7 W or less 0.8 W or less 0.9 W or less
Job indicator OFF 0.6 W or less 0.7 W or less 0.8 W or less
Output <NPN output type>
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less (between output and 0 V)
・Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
<PNP output type>
PNP open-collector transistor
・Maximum source current: 100 mA
・Applied voltage: 30 V DC or less (between output and +V)
・Residual voltage: 1 V or less (at 100 mA source current)
0.4 V or less (at 16 mA source current)
Utilization category DC-12 or DC-13
Output operation ON when all beam channels are received
(OFF when one or more beam channels are interrupted)
Short-circuit protection Incorporated
Response time 10 ms or less
(12 ms or less when the interference prevention function is used)
Indicators Emitter Emitting indicator: Green LED x 2 (light up during emission; one LED lights up for Frequency A setting, both LEDs light up for Frequency B setting)
Job indicator: Red LED (lights up, blinks or lights off when the job indicator input is applied, selected by operation mode switch)
Receiver Operation indicator: Red LED (lights up when one or more beam channels are interrupted)
Stable incident beam indicator: Green LED (lights up when all beam channels are stably received)
Job indicator: Red LED (lights up, blinks or lights off when the job indicator input is applied, selected by operation mode switch)
* When an excess current flows through the output, the stable incident beam indicator and the operation indicator on the receiver blink simultaneously due to operation of the short-circuit protection circuit.
Interference prevention function Incorporated
Test input (emission halt) function Incorporated
Pollution degree 3 (Industrial environment)
Ambient temperature -10 to +55 °C +14 to +131 °F
(No dew condensation or icing allowed),
Storage: -10 to +60 °C +14 to +140 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 lx at the light-receiving face
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Emitting element Infrared LED
(Peak emission wavelength: 950 nm 0.037 mil, modulated)
Material Enclosure: Heat-resistant ABS, Lens cover: Polyester, Indicator cover: Acrylic
Cable 0.2 mm2 4-core cabtyre cable, 3 m 9.843 ft long
Cable extension Extension up to total 25 m 82.021 ft is possible for both emitter and receiver, with 0.2 mm2, or more, cable.
Weight
(Total weight of emitter and receiver)
Net weight: 350 g approx.
Gross weight: 550 g approx.
Net weight: 400 g approx.
Gross weight: 600 g approx.
Net weight: 450 g approx.
Gross weight: 650 g approx.

^ Back to top

Number of beam channels 20 24 28
Model No. NPN output NA2-N20 NA2-N24 NA2-N28
PNP output NA2-N20-PN NA2-N24-PN NA2-N28-PN
Sensing height 380 mm 14.961 in 460 mm 18.110 in 540 mm 21.260 in
Sensing range 5 m 16.404 ft
Beam pitch 20 mm 0.787 in
Sensing object ø30 mm ø1.181 in or more opaque object
(completely beam interrupted objects)
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Power consumption (Note 2) Emitter Job indicator ON 1.0 W or less 1.1 W or less 1.2 W or less
Job indicator OFF 0.9 W or less 1.0 W or less 1.1 W or less
Receiver Job indicator ON 1.0 W or less 1.1 W or less 1.2 W or less
Job indicator OFF 0.9 W or less 1.0 W or less 1.1 W or less
Output <NPN output type>
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less (between output and 0 V)
・Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
<PNP output type>
PNP open-collector transistor
・Maximum source current: 100 mA
・Applied voltage: 30 V DC or less (between output and +V)
・Residual voltage: 1 V or less (at 100 mA source current)
0.4 V or less (at 16 mA source current)
Utilization category DC-12 or DC-13
Output operation ON when all beam channels are received
(OFF when one or more beam channels are interrupted)
Short-circuit protection Incorporated
Response time 10 ms or less
(12 ms or less when the interference prevention function is used)
Indicators Emitter Emitting indicator: Green LED x 2 (light up during emission; one LED lights up for Frequency A setting, both LEDs light up for Frequency B setting)
Job indicator: Red LED (lights up, blinks or lights off when the job indicator input is applied, selected by operation mode switch)
Receiver Operation indicator: Red LED (lights up when one or more beam channels are interrupted)
Stable incident beam indicator: Green LED (lights up when all beam channels are stably received)
Job indicator: Red LED (lights up, blinks or lights off when the job indicator input is applied, selected by operation mode switch)
* When an excess current flows through the output, the stable incident beam indicator and the operation indicator on the receiver blink simultaneously due to operation of the short-circuit protection circuit.
Interference prevention function Incorporated
Test input (emission halt) function Incorporated
Pollution degree 3 (Industrial environment)
Ambient temperature -10 to +55 °C +14 to +131 °F
(No dew condensation or icing allowed),
Storage: -10 to +60 °C +14 to +140 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 lx at the light-receiving face
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Emitting element Infrared LED (Peak emission wavelength: 950 nm 0.037 mil, modulated)
Material Enclosure: Heat-resistant ABS, Lens cover: Polyester, Indicator cover: Acrylic
Cable 0.2 mm2 4-core cabtyre cable, 3 m 9.843 ft long
Cable extension Extension up to total 25 m 82.021 ft is possible for both emitter and receiver, with 0.2 mm2, or more, cable.
Weight
(Total weight of emitter and receiver)
Net weight: 500 g approx.
Gross weight: 700 g approx.
Net weight: 570 g approx.
Gross weight: 750 g approx.
Net weight: 650 g approx.
Gross weight: 800 g approx.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) Obtain the current consumption from the following equation.
Current consumption = Power consumption ÷ Supply voltage
(e.g.) In case of NA2-N8 (when job indicator lights up)
When the supply voltage is 12 V, the current consumption of the emitter is: 0.7 W ÷ 12 V ≈ 0.058 A = 58 mA.

^ Back to top