Product name Type Number of point Connection method Specifications Number
FP2 Input unit DC input 16 points Terminal 12 to 24V DC FP2-X16D2
32 points Connector 24V DC FP2-X32D2
64 points Connector 24V DC FP2-X64D2
FP2 Output unit Relay output 6 points Terminal 5 A, 2 points per one common FP2-YR6
16 points Terminal 2 A, 8 points per one common FP2-Y16R
Transistor output NPN 16 points Terminal 0.5 A (12 to 24 V DC), 0.1 A (5 V DC) FP2-Y16T
32 points Connector 0.1A(12 to 24V DC), 50mA (5V DC) FP2-Y32T
64 points Connector 0.1A(12 to 24V DC), 50mA (5V DC) FP2-Y64T
Transistor output PNP 16 points Terminal 0.5 A (12 to 24 V DC), 0.1 A (5 V DC) FP2-Y16P
32 points Connector 0.1A(12 to 24V DC), 50mA (5V DC) FP2-Y32P
64 points Connector 0.1A(12 to 24V DC), 50mA (5V DC) FP2-Y64P
FP2 I/O mixed unit DC input, Transistor output NPN Input 32 points, Output 32 points Connector Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) FP2-XY64D2T
Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) with on pulse catch input FP2-XY64D7T
DC input, Transistor output PNP Input 32 points, Output 32 points Connector Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) FP2-XY64D2P
Input 24 V DC Output 0.1 A (12 to 24 V DC), 50 mA (5 V DC) with on pulse catch input FP2-XY64D7P

Notes:
* Pressure welding socket is supplied. A special tool (Part number AXY52000) is needed for connection.
* Please purchase separately if you are using a terminal or flat cable socket.

^ Back to top

Intelligent Units

Analog I/O Unit

Product name Specifications Number of I/O points Part Number
FP2 Analog Input unit Channel isolation multi input
Voltage range: 1 to 5V, -10 to +10V, -100 to +100mV
Resolution: 1/13017(1 to 50V) to 1/65536(Others)
Thermocouple: S, J, K, T, R, N type
R.T.D.: Pt100, JPt100, Pt1000
Analog input:
8 ch.
FP2-AD8X
R.T.D. input
R.T.D.: Pt100, JPt100, Pt1000
FP2-RTD
Voltage/Current input
Voltage range: 1 to +5 V, -10 to +10V
Current range: 4 to 20 mA, -20 to +20mA
Resolution: 1/13107 (1 to 5 V, 4 to 20mA) to 1/65536(Others)
FP2-AD8
FP2 Analog Output unit Voltage range: -10 to +10 V
Current range: 0 to 20 mA
Resolution: 1/4096
Analog output:
4 ch.
FP2-DA4

^ Back to top

Positioning control and Calculation units

Product name Specifications Part Number
Output type Number of axes controlled Speed command
FP2 Positioning unit Multifunction type note 1) Transistor 2 axes, independent 1pps to 500kpps FP2-PP21
4 axes, independent FP2-PP41
Line driver 2 axes, independent 1pps to 4Mpps FP2-PP22
4 axes, independent FP2-PP42
FP2 Positioning unit RTEX 2 axes unit FP2-PN2AN
4 axes unit FP2-PN4AN
8 axes unit FP2-PN8AN
Dedicated software toolConfigurator PM (English) AFPS66510
FP2 High-speed counter unit 8 interrupt inputs 4-channel high-speed counter 8 comparison outputs Input: 24 V DC Output: 5 to 24 V DC (0.1 A, 12 points/0.8 A, 4 points) NPN output FP2-HSCT
PNP output FP2-HSCP
FP2 Pulse I/O unit 8 interrupt inputs 4-channel high-speed counter 8 comparison outputs 4 pulse output channels 4 PWM output channels Input: 24 V DC Output: 5 to 24 V DC (0.1 A, 12 points/0.8 A, 4 points) NPN output FP2-PXYT
PNP output FP2-PXYP

Notes:
1) Previous FP2 positioning units AFP2430 (FP2-PP2) and AFP2431 (FP2-PP4) are not compatible with the multi-function type FP2 positioning unit. Please contact us.
* Pressure welding socket is supplied. A special tool (part no. AXY52000) is needed for connection.
Please purchase separately if you are using a terminal or flat cable socket.
* Please refer to "FP SIGMA Product Types" for Motor driver I/F terminal II.

^ Back to top

Link/Communication Units

Serial Communication/Network Units

Product name Specifications Part Number
FP2 Multi communication unit Selectable combination of two interfaces from RS232C/RS422/RS485 detachable serial communication block. FP2-MCU
Communication block RS232C FP2-CB232
RS422 FP2-CB422
RS485 FP2-CB485

Notes:
* FP2 Muti Communication Unit cannot be used alone. Use it with FP2 communication block.

^ Back to top

Unit for Serial data controls

Product name Specifications Number of channel Part Number
FP2 Serial data unit The unit can communicate with RS232C device. The serial input/output is executed by sequence instruction. 2 ch. FP2-SDU

Notes:
* For wiring, use the accompanying D-SUB connector or a separately sold cable.

^ Back to top

Unit for Display panel and Computer interface

Product name Specifications Number of channel Part Number
FP2 Computer communication unit The unit can communicate with a computer in 1: 1 communication. RS232C×2 channels The unit can also be connected with operation display panel. 2 ch. FP2-CCU

Notes:
* For wiring, use the accompanying D-SUB connector or a separately sold cable.

^ Back to top

Link-related units and software

Product name Specifications Part Number
FP2 Multi-wire link unit Can connect as the remote I/O system MEWNET-F master station. Perfect for remote I/O systems using many points FP2-MW
FP2 S-Link unit Direct connection to SUNX Co., Ltd., S-LINK reduced-wiring system CPU unit with 128 points × 1 channel FP2-SL2
FP2 ET-LAN unit Ethernet link unit for FP2/FP2SH Installed on CPU backplane. FP2-ET1
Control
Configurater ET
ET-LAN unit setting software AFPS32510

^ Back to top

Backplane

Product name Specifications Part Number
FP2 Backplane 5-module type (for basic) FP2-BP05
7-module type (for basic and expansion) FP2-BP07
9-module type (for basic and expansion) FP2-BP09
12-module type (for basic and expansion) FP2-BP12
14-module type (for basic and expansion) FP2-BP14
FP2 Backplane H type. 11-module type (for basic) FP2-BP11MH
10-module type (for expansion) FP2-BP10EH
FP2 Expansion cable 0.6m FP2-EC
2m FP2-EC2

^ Back to top

Power Supply Unit

Product name Specifications Part Number
FP2 Power supply unit Input: 100 to 120 V AC, Output: 2.5 A FP2-PSA1
Input: 200 to 240 V AC, Output: 2.5 A FP2-PSA2
Input: 100 to 240 V AC, Output: 5 A FP2-PSA3
Input: 24 V DC, Output: 5 A FP2-PSD2

^ Back to top

Optional memories

For FP2

Product name Functions Part Number
Functions Clock/Calendar Expansion RAM ROM socket
Expansion memory unit Available Available Not available Not available FP2-EM1
Available Available Available Not available FP2-EM2
Available Available Available Available FP2-EM3
Not available Not available Available Available FP2-EM6
Not available Not available Not available Available FP2-EM7
F-ROM FLASH-ROM for program copy and ROM operation
Equivalent to SST-29EE010-120-4C-PH
Enables writing with the programming tool when attached to the CPU unit.
FP2-EM4
EP-ROM EP-ROM for program storage and ROM operation
Equivalent to M27C1001-12F1
A commercially available ROM writer is required.
FP2-EM5

^ Back to top

For FP2SH

Product name Specifications Part Number
ROM for FP2SH
standard type
CPU unit
Expansion
memory unit
Socket for fitting ROM to the CPU unit FP2-EM7
F-ROM FLASH-ROM for program copy and ROM operation
Equivalent to SST-29EE020-150-4C-PH Enables writing with the programming tool when attached to the CPU unit.
AFP5208
EP-ROM EP-ROM for program storage and ROM operation
Equivalent to M27C2001-150F1
A commercially available ROM writer is required.
AFP5209
IC memory card (Small PC card)
for FP2SH CPU unit with
IC memory card interface
F-ROM Backup unnecessary. Perfect for program memory
Used for readout when using data memory.
AIC50020
SRAM Perfect for data memory
Can also be used for program backup.
Battery backups.
AIC52000

^ Back to top



Partners Contact Corporate International Log In