PM4H/4S Timers Specifications
Specifications for this product appear below.
PM4H - A/S/M Multi-Range Timers
| Type Item | PM4H-A | PM4H-S | PM4H-M | ||
|---|---|---|---|---|---|
| Rating | Rated operating voltage | 100 to 240V AC, 48 to 125V DC, 12V DC, 24V AC/DC | |||
| Rated frequency | 50/60Hz common (AC operating type) | ||||
| Rated power consumption | Approx. 10VA (100 to 240V AC) Approx. 2.5VA (24V AC) Approx. 2W (12V DC, 24V DC, 48 to 125V DC) |
||||
| Output rating | 5A 250V AC (resistive load) | ||||
| Operating mode | Pulse ON-delay Pulse Flicker Pulse ON-flicker Differential ON/OFF-delay (1) (2) Signal OFF-delay Pulse One-shot Pulse One-cycle |
Power ON-delay | Power ON-delay Power Flicker Power ON-flicker Power One-shot Power One-cycle (with instantaneous contact) |
||
| Time range | 1s to 500h (Max.) 16 time ranges switchable | ||||
| Time accuracy Note:) | Operating time fluctuation | ±0.3% (power off time change at the range of 0.1s to 1h) | |||
| Setting error | ±5% (Full-scale value) | ||||
| Voltage error | ±0.5% (at the operating voltage changes between 85 to 110%) | ||||
| Temperature error | ±2% (at 20°C ambient temp. at the range of -10 to +50°C/ +14 to +122°F) | ||||
| Contact | Contact arrangement | Timed-out 2 Form C | Timed-out 1 Form C Instantaneous 1 Form C | ||
| Contact resistance (Initial value) | Max. 100mΩ (at 1A 6V DC) | ||||
| Contact material | Silver alloy | Au flash on Silver alloy | |||
| Life | Mechanical (contact) | 2×107 | |||
| Electrical (contact) | 105(at rated control capacity) | ||||
| Electrical function | Allowable operating voltage range | 85 to 110% of rated operating voltage (at 20°C coil temp.) | |||
| Insulation resistance (Initial value) | Min. 100MΩ Between live and dead metal parts Between input and output Between contacts of different poles Between contacts of same pole (At 500V DC) |
||||
| Breakdown voltage (Initial value) | 2, 000Vrms for 1 min Between live and dead metal parts 2, 000Vrms for 1 min Between input and output 2, 000Vrms for 1 min Between contacts of different poles 1, 000Vrms for 1 min Between contacts of same pole |
||||
| Min. power off time | 100ms | ||||
| Max. temperature rise | 55°C/ 131°F | 65°C/ 149° F | |||
| Mechanical function | Shock resistance | Functional | Min. 98m/s2(4 times on 3 axes) | ||
| Destructive | Min. 980m/s2(5 times on 3 axes) | ||||
| Vibration resistance | Functional | 10 to 55Hz: 1 cycle/min double amplitude of 0.5mm (10min on 3 axes) | |||
| Destructive | 10 to 55Hz: 1 cycle/min double amplitude of 0.75mm (1h on 3 axes) | ||||
| Operating condition | Ambient temperature | -10 to +50°C/ +14 to +122 °F | |||
| Ambient humidity | 30 to 85%RH (at 20°C/ 68°F, non-condensing) | ||||
| Atmospheric pressure | 860 to 1, 060hPa | ||||
| Ripple factor (DC type) | 20% | ||||
| Others | Protective construction | IP65 on front panel (using rubber gasket ATC18002) (only for IP65 type) | |||
| Weight | 100g/ 3.527oz (Pin type) | ||||
| 110g/ 3.880oz (Screw terminal type) | |||||
Notes:
1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple factor for DC), 20°C/ 68°F ambient temperature, and 1s power off time.
2) For the 1s range, the tolerance for each specification becomes ±10ms.
PM4H - SD/SDM - Star/Delta Timers
| Type Item | PM4H-SD/SDM | ||
|---|---|---|---|
| Rating | Rated operating voltage | 100 to 240V AC, 24V AC | |
| Rated frequency | 50/60Hz common | ||
| Rated power consumption | Approx. 6VA (100 to 240V AC) Approx. 1.4VA (24V AC) | ||
| Rated control capacity | 5A 250V AC (resistive load) | ||
| Operation mode | -star-delta switching (Power ON-delay) | ||
| operation control time range | 2s to 100s, 4 time ranges switchable | ||
| - switching time | 0.04, 0.1, 0.3, 0.5, 0.7s (5 time range selectable) | ||
| Time accuracy Note:) | Operation time fluctuation | ±0.3% (power off time change at the range of 0.1s to 1h) | |
| Setting error | ±5% (Max. setting time value) | ||
| Voltage error | ±0.5% (at the operating voltage changes between 85 to 110%) | ||
| Temperature error | ±2% (at 20°C ambient temp. at the range of -10 to +50°C +14 to +122°F) | ||
| Contact | Contact arrangement | Star () side: Timed-out 1 Form A Delta () side: Timed-out 1 Form A Instantaneous: 1 Form A (Instantaneous for PM4H-SDM type only) |
|
| Contact resistance (Initial value) | Max. 100mohm (at 1A 6V DC) | ||
| Contact material | Au flash on Silver alloy | ||
| Life | Mechanical (contact) | 2×107 | |
| Electrical (contact) | 105 (at rated control capacity) | ||
| Electrical function | Allowable operating voltage range | 85 to 110% of rated operating voltage (at 20°C coil temp.) | |
| Insulation resistance (Initial value) | Min. 100Mohm Between live and dead metal parts Between input and output Between contacts of different poles *3 Between contacts of same pole (At 500V DC) |
||
| Breakdown voltage (Initial value) | 2, 000Vrms for 1 min Between live and dead metal parts 2, 000Vrms for 1 min Between input and output 2, 000Vrms for 1 min Between contacts of different poles *3 1, 000Vrms for 1 min Between contacts of same pole |
||
| Min. power off time | 500ms | ||
| Max. temperature rise | 65°C/ 131°F | ||
| Mechanical function | Vibration resistance | Functional | 10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes) |
| Destructive | 10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes) | ||
| Shock resistance | Functional | Min. 294m/s2 (4 times on 3 axes) | |
| Destructive | Min. 980m/s2 (5 times on 3 axes) | ||
| Operating condition | Ambient temperature | -10 to +50°C/ +14 to +122°F | |
| Ambient humidity | Max. 85%RH (non-condensing) | ||
| Atmospheric pressure | 860 to 1, 060hPa | ||
| Others | Protective construction | IP65 on front panel (using rubber gasket ATC 18002) |
|
| Weight | 100g/ 3.527 oz (Pin type), 110g/ 3.880 oz (Screw terminal type) | ||
Notes:
1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage, 20°C/ 68°F ambient temperature, and 1s power off time.
2) For the 2s range, the tolerance for each specification becomes ±10ms.
3) Between contacts of different poles for SDM type only.
PM4H - F Off-delay Timers
| Type Item | PM4H-F8 | PM4H-F8R | PM4H-F11R | ||
|---|---|---|---|---|---|
| Rating | Rated operating voltage | 100 to 120V AC, 200 to 240V AC, 24V AC, 12V DC, 24V DC | |||
| Rated frequency | 50/60Hz common (AC operating type) | ||||
| Rated power consumption | Approx. 1.6VA (100 to 120V AC, 200 to 240V AC), Approx. 2.3VA (24V AC) Approx. 1.1W (12V DC, 24V DC) |
||||
| Rated control capacity | 3A 250V AC (resistive load) | ||||
| Operation mode | Power OFF-delay | Power OFF-delay (with reset) | |||
| Time range | 1s to 10s: 3 range switchable 1min to 10 min: 3 range selectable | ||||
| Time accuracy *1 | Operation time fluctuation | ±0.3% | |||
| Setting error | ±5% (Max. setting time value) | ||||
| Voltage error | ±0.5% (at the operating voltage changes between 85 to 110%) | ||||
| Temperature error | ±2% (at 20°C ambient temp. at the range of -10 to +50°C +14 to +122°F) | ||||
| Contact | Contact arrangement | Timed-out 2 Form C | Timed-out 1 Form C | Timed-out 2 Form C | |
| Contact resistance (Initial value) | Max. 100mohm (at 1A 6V DC) | ||||
| Contact material | Au flash on Silver alloy | ||||
| Life | Mechanical (contact) | 107 | |||
| Electrical (contact) | 105 (at rated control capacity) | ||||
| Electrical function | Allowable operating voltage range | 85 to 110% of rated operating voltage (at 20°C coil temp.), 90 to 110% (DC Type) | |||
| Insulation resistance (Initial value) | Min. 100Mohm Between live and dead metal parts Between input and output Between contacts of different poles *3 Between contacts of same pole (At 500V DC) |
||||
| Breakdown voltage (Initial value) | 1, 500Vrms for 1 min Between live and dead metal parts 1, 500Vrms for 1 min Between input and output 1, 000Vrms for 1 min Between contacts of different poles *3 750Vrms for 1 min Between contacts of same pole |
||||
| Min. power supply width | s range type: 100ms min range type: 2s |
||||
| Min. reset time | - | 50ms | |||
| Max. temperature rise | 55°C/ 131°F | ||||
| Mechanical function | Vibration resistance | Functional | 10 to 55Hz: 1 cycle/min double amplitude of 0.5mm (10min on 3 axes) | ||
| Destructive | 10 to 55Hz: 1 cycle/min double amplitude of 0.75mm (1h on 3 axes) | ||||
| Shock resistance | Functional | Min. 98m/s2 (4 times on 3 axes) | |||
| Destructive | Min. 980m/s2 (5 times on 3 axes) | ||||
| Operating condition | Ambient temperature | -10 to +50°C/ +14 to +122°F | |||
| Ambient humidity | 30 to 85%RH (non-condensing) | ||||
| Atmospheric pressure | 860 to 1, 060hPa | ||||
| Ripple factor (DC type) | 20% | ||||
| Others | Protective construction | IP65 on front panel (using rubber gasket ATC 18002) (only for IP65 type) |
|||
| Weight | 100g/ 3.527 oz (Pin type), 110g/ 3.880 oz (Screw terminal type) | ||||
Notes:
1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple factor for DC), 20°C/ 68°F ambient temperature.
2) For the 1s range, the tolerance for each specification becomes ±10ms. When the power goes on, in rush current (0.3A) flows. Cautions should be taken. The minimum power supplying time after forced reset input is 2s or more.
3) Between contacts of different pools for F8, F11R types only.
PM4H - W Twin Timers
| Type Item | PM4H-W | ||
|---|---|---|---|
| Rating | Rated operating voltage | 100 to 240V AC, 12V DC, 24V AC/DC, 48 to 125V | |
| Rated frequency | 50/60Hz common (AC operating type) | ||
| Rated power consumption | Approx. 10VA (100 to 240V AC) Approx. 2.5VA (24V AC) Approx. 2W (12V DC, 24V DC, 48 to 125V DC) | ||
| Output rating | 5A 250V AC (resistive load) | ||
| Operation mode | Cyclic (OFF-start/Twin operation) | ||
| Time range | 1s to 500h 16 time ranges switchable (T1, T2time setting individually) | ||
| Time accuracy Note:) | Operation time fluctuation | ±0.3% (power off time change at the range of 0.1s to 1h) | |
| Setting error | ±5% (Max. setting time value) | ||
| Voltage error | ±0.5% (at the operating voltage changes between 85 to 110%) | ||
| Temperature error | ±2% (at 20°C ambient temp. at the range of -10 to +50°C/ +14 to +122 °F) | ||
| Contact | Contact arrangement | Timed-out 2 Form C | |
| Contact resistance (Initial value) | Max. 100mohm (at 1A 6V DC) | ||
| Contact material | Silver alloy | ||
| Life | Mechanical | 2×107 | |
| Electrical | 105(at rated control capacity) | ||
| Electrical function | Allowable operating voltage range | 85 to 110% of rated operating voltage (at 20°C coil temp.) | |
| Insulation resistance (Initial value) | Min. 100Mohm Between live and dead metal parts Between input and output Between contacts of different poles Between contacts of same pole (At 500V DC) | ||
| Breakdown voltage (Initial value) | 2, 000Vrms for 1 min Between live and metal parts 2, 000Vrms for 1 min Between input and output 2, 000Vrms for 1 min Between contacts of different poles 1, 000Vrms for 1 min Between contacts of same pole | ||
| Min. power off time | 300ms | ||
| Max. temperature rise | 55°C/ 131 °F | ||
| Mechanical function | Shock resistance | Functional | Min. 98m/s2(4 times on 3 axes) |
| Destructive | Min. 980m/s2(5 times on 3 axes) | ||
| Vibration resistance | Functional | 10 to 55Hz: 1 cycle/min double amplitude of 0.5mm (10min on 3 axes) | |
| Destructive | 10 to 55Hz: 1 cycle/min double amplitude of 0.75mm (1h on 3 axes) | ||
| Operating condition | Ambient temperature | -10 to +50°C/ +14 to +122 °F | |
| Ambient humidity | Max. 85%RH | ||
| Atmospheric pressure | 860 to 1, 060hPa | ||
| Ripple factor (DC type) | 20% | ||
| Others | Protective construction | IP65 on front panel (using rubber gasket ATC 18002) (only for IP65 type) | |
| Weight | 120g/ 4.233 oz (Pin type), 130g/ 4.586 oz(Screw terminal type) | ||
Notes:
1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple factor for DC), 20°C/ 68°F ambient temperature, and 1s power off time.
2) For the 1s range, the tolerance for each specification becomes ±10ms.
PM4S - Multi-range Timers
| Type | PM4S Multi-range Timer | ||||||
|---|---|---|---|---|---|---|---|
| Item | |||||||
| Rating | Rated operating voltage | 100 to 120V AC | 200 to 240V AC | 12V DC | 24V DC | ||
| Rated frequency | 50/60 Hz | - | |||||
| Rated power consumption | Approx. 3.0VA/3.6VA (at 100V AC) Approx. 4.5VA/5.25VA (at 120V AC) |
Approx. 5.6VA/6.8VA (at 200V AC) Approx. 7.5VA/9.8VA (at 240V AC) |
Approx1.3W | Approx1.7W | |||
| Output rating | 5A 250V AC (resistive load) | ||||||
| Operating mode | Power ON-delay | ||||||
| Time range | A type | 1s/10s/1min/10min (4 time ranges selectable) | |||||
| B type | 3s/30s/3min/30min (4 time ranges selectable) | ||||||
| C type | 6s/60s/6min/60min (4 time ranges selectable) | ||||||
| D type | 1min/10min/1h/10h (4 time ranges selectable) | ||||||
| E type | 3min/30min/3h/30h (4 time ranges selectable) | ||||||
| Time accuracy Note) | Operating time fluctuation | ±1% (power off time change at the range of 0.1s to 1h) | |||||
| Setting error | ±5% (Full-scale value) | ||||||
| Voltage error | ±1% (at the operating voltage changes between 85 to 110%) | ||||||
| Temperature error | ±2% (at 20°C ambient temp. at the range of 10 to +50°C/ +14 to +122°F) | ||||||
| Contact | Contact arrangement | T.D.: Timed-out 2 Form C INST.: Timed-out 1 Form C, instantaneous 1 Form C (Selected by front switch) |
|||||
| Contact resistance (Initial value) |
Max. 100m ohm; (at 1A 6V DC) | ||||||
| Contact material | Silver alloy | ||||||
| Life | Mechanical (contact) | Min. 107 | |||||
| Electrical (contact) | Min. 105(at raed control capacity) | ||||||
| Electrical function | Allowable operating voltage range | 85 to 110% of rated operating voltage | |||||
| Insulation resistance (Initial value) |
Min. 100Mohm Between live and dead metal parts Between input and output Between contacts of different poles Between contacts of same pole (At 500V DC) |
||||||
| Breakdown voltage (Initial value) |
2,000Vrms for 1 min Between live and dead metal parts 2,000Vrms for 1 min Between input and output 2,000Vrms for 1 min Between contacts of different poles 1,000Vrms for 1 min Between contacts of same pole |
||||||
| Min. power off time | 100 ms | ||||||
| Max. temperature rise | 55°C/ 131°F | ||||||
| Mechanical function | Vibration resistance | Functional | 10 to 55Hz: 1 cycle/min double amplitude of 0.25mm (10min on 3 axes) | ||||
| Destructive | 10 to 55Hz: 1 cycle/min double amplitude of 0.375mm (1h on 3 axes) | ||||||
| Shock resistance | Functional | Min. 98m/s2 (4 times on 3 axes) | |||||
| Destructive | Min. 980m/s2(5 times on 3 axes) | ||||||
| Operating condition | Ambient temperature | -10 to 50°C/ +14 to +122°F | |||||
| Ambient humidity | 30 to 85%RH (non-condensing) | ||||||
| Atmospheric pressure | 860 to 1,060hPa | ||||||
| Ripple factor (DC type) |
20% | ||||||
| Others | Weight | approx. 110g/ 3.880 oz | |||||
Notes:
1) Unless otherwise specified, the measurement conditions at the maximum scale time standard are specified to be the rated operating voltage (within 5% ripple factor for DC), 20°C/ 68°F ambient temperature, and 1s power off time.
2) For the 1s range, the tolerance for each specification becomes ±10ms.