GXL Proximity Sensors Specifications

Proximity Sensors GXL

Specifications for this product appear below.

DC 2-wire type

Type GXL-8 type
Front sensing Top sensing
Standard Model No. GXL-8FU GXL-8HU
Max. operation distance (Note 3) 2.5 mm 0.098 in ± 20%
Stable sensing range (Note 3) 0 to 1.8 mm 0 to 0.071 in
Standard sensing object Iron sheet 15 x 15 x t 1 mm
0.591 x 0.591 x t 0.039 in
Hysteresis 20 % or less of operation distance
(with standard sensing object)
Repeatability Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption (Note 4) 0.8 mA or less
Output Non-contact DC 2-wire type
・Load current: 3 to 70 mA (Note 5)
・Residual voltage: 3 V or less (Note 6)
Utilization category DC-12 or DC-13
Short-circuit protection Incorporated
Max. response frequency 1 kHz
Operation indicator Normally closed type: Red LED
(lights up when the output is ON)
2-color indicator Normally open type: Lights up in green under stable sensing condition
Lights up in red under unstable sensing condition
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC), IP67 g (JEM)
Ambient temperature -25 to +70 ℃ -13 to +158 ℉, Storage: -30 to +80 ℃ -22 to +176 ℉
Ambient humidity 45 to 85 % RH, Storage: 35 to 95 % RH
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Sensing
range
variation
Temperature characteristics Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉
: Within+15-10 % of sensing range at +20 ℃ +68 ℉
Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage
Material Enclosure: PBT, Indicator part: Polyalylate
Cable (Note 7) 0.15 mm2 2-core oil, heat and cold resistant cable, 1 m 3.281 ft long
Cable extension Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Weight Net weight: 12 g approx.
Accessories MS-GXL8-4
(Sensor mounting bracket): 1 set

^ Back to top

Type GXL-15 type
Standard Long sensing range
(For mounting on non-magnetic body)
(Note 2)
Front sensing Top sensing Front sensing Top sensing
Standard Model No. GXL-15FU GXL-15HU GXL-15FLU GXL-15HLU
Max. operation distance (Note 3) 5 mm 0.197 in ± 10% 8 mm 0.315 in ± 10%
Stable sensing range (Note 3) 0 to 4 mm
0 to 0.157 in
0 to 6.4 mm
0 to 0.252 in
Standard sensing object Iron sheet 20 x 20 x t 1 mm
0.787 x 0.787 x t 0.039 in
Iron sheet 30 x 30 x t 1 mm
1.181 x 1.181 x t 0.039 in
Hysteresis 20 % or less of operation distance
(with standard sensing object)
Repeatability Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption (Note 4) 0.8 mA or less
Output Non-contact DC 2-wire type
・Load current: 3 to 100 mA (Note 5)
・Residual voltage: 3 V or less (Note 6)
Utilization category DC-12 or DC-13
Short-circuit protection Incorporated
Max. response frequency 1 kHz
Operation indicator Normally closed type: Red LED
(lights up when the output is ON)
2-color indicator Normally open type: Lights up in green under stable sensing condition
Lights up in red under unstable sensing condition
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC), IP67 g (JEM)
Ambient temperature -25 to +70 ℃ -13 to +158 ℉, Storage: -30 to +80 ℃ -22 to +176 ℉
Ambient humidity 45 to 85 % RH, Storage: 35 to 95 % RH
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Sensing
range
variation
Temperature characteristics Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉
: Within+15 -10 % of sensing range at +20 ℃ +68 ℉
Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage
Material Enclosure: PBT, Indicator part: Polyalylate Enclosure: PET
Indicator part:
Polyalylate
Enclosure: PBT
Indicator part:
Polyalylate
Enclosure: PET
Indicator part:
Polyalylate
Cable (Note 7) 0.2 mm2 2-core oil, heat and cold resistant cable, 1 m 3.281 ft long
Cable extension Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Weight Net weight: 20 g approx.
Accessories - MS-A15F
(Aluminum sheet):
1 pc.
MS-A15H
(Aluminum sheet):
1 pc.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2) To mount the long sensing range GXL-15FLU/15HLU type on a magnetic body, such as iron, the enclosed aluminum sheet, or any other aluminum sheet having a minimum size of 30 x 39.5 x t 0.3 mm 1.181 x 1.555 x t 0.012 in (GXL-15HLU type: 30 x 30 x t 0.3 mm 1.181 x 1.181 x t 0.012 in), should be inserted between the sensor and the magnetic body.
However, it is not necessary to use the aluminum sheet when mounting on a non-magnetic body, such as, aluminum or an insulator.
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
4) It is the leakage current when the output is in the OFF state.
5) The maximum load current varies with the ambient temperature.
6) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable.
The residual voltage of 5 m 16.404 ft cable length type increases by +0.1 V.
7) The flexible cable type (model No. with suffix "-R") has a 0.15 mm2 (GXL-15 type: 0.2 mm2) flexible, oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long.

^ Back to top

NPN output types

Type GXL-8 type GXL-N12 type
Cable
type
Terminal
type
Front sensing Top sensing Front sensing
Standard Model No. GXL-8F GXL-8H GXL-N12F GXL-N12FT
Max. operation distance (Note 3) 2.5 mm 0.098 in ± 20% 3 mm 0.118 in ± 10%
Stable sensing range
(Note 3)
0 to 1.8 mm
0 to 0.071 in
0 to 2 mm
0 to 0.079 in
Standard sensing object Iron sheet 15 x 15 x t 1 mm
0.591 x 0.591 x t 0.039 in
Iron sheet 20 x 20 x t 1 mm
0.787 x 0.787 x t 0.039 in
Hysteresis 20 % or less of operation distance
(with standard sensing object)
Repeatability Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption 15 mA or less
Output NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less (between output and 0 V)
・Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
Utilization category DC-12 or DC-13
Short-circuit protection -
Max. response frequency 500 Hz
Operation indicator Red LED (lights up when the output is ON)
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC), IP67 g (JEM) except for the terminal type
Ambient temperature -10 to +55 ℃ 14 to +131 ℉,
Storage: -30 to +80 ℃ -22 to +176 ℉
Ambient humidity 45 to 85 % RH, Storage: 35 to 95 % RH
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Sensing
range
variation
Temperature characteristics Over ambient temperature range -10 to +55 ℃ +14 to +131 ℉
: Within +15-10 % of sensing range at +20 ℃ +68 ℉
Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage
Material Enclosure: PBT, Indicator part: Polyalylate
Cable (Note 4) 0.08 mm2 3-core oil,
heat and cold resistant
cabtyre cable,
1 m 3.281 ft long
0.15 mm2 3- core oil,
heat and cold resistant
cabtyre cable,
1 m 3.281 ft long
-
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight 12 g approx. 20 g approx. 5 g approx.
Accessories MS-GXL8 (Sensor mounting bracket): 1 set MS-GXL12-1 (Sensor mounting bracket): 1 pc.
M3 pan head screw, plain washer, spring washer and nut: 1 set
MS-R1 (Rubber washer): 1 pc.

^ Back to top

Type GXL-15 type
Standard Long sensing range
(For mounting on
non-magnetic body)
(Note 2)
Front sensing Top sensing Top sensing
Standard Model No. GXL-15F GXL-15H GXL-15HL
Max. operation distance (Note 3) 5 mm 0.197 in ± 10% 8 mm 0.315 in ± 10%
Stable sensing range (Note 3) 0 to 4 mm
0 to 0.157 in
0 to 6.4 mm
0 to 0.252 in
Standard sensing object Iron sheet 20 x 20 x t 1 mm
0.787 x 0.787 x t 0.039 in
Iron sheet 30 x 30 x t1 mm
1.181 x 1.181 x t0.039 in
Hysteresis 20 % or less of operation distance
(with standard sensing object)
Repeatability Along sensing axis, perpendicular to sensing axis: 0.04 mm
0.002 in or less
Along sensing axis, perpendicular to sensing axis: 0.06 mm 0.002 in or less
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption 15 mA or less
Output NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less (between output and 0 V)
・Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
Utilization category DC-12 or DC-13
Short-circuit protection -
Max. response frequency 250 Hz
Operation indicator Red LED (lights up when the output is ON)
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC), IP67 g (JEM) except for the terminal type
Ambient temperature -10 to +55 ℃ 14 to +131 ℉, Storage: -30 to +80 ℃ -22 to +176 ℉
Ambient humidity 45 to 85 % RH, Storage: 35 to 95 % RH
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Sensing
range
variation
Temperature characteristics Over ambient temperature range -10 to +55 ℃ +14 to +131 ℉
: Within +15/ -10 % of sensing range at +20 ℃ +68 ℉
Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage
Material Enclosure: PBT, Indicator part: Polyalylate Enclosure: PET
Indicator part: Polyalylate
Cable (Note 4) 0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight 20 g approx.
Accessories - MS-A15H
(Aluminum
sheet): 1 pc.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2) To mount the long sensing range GXL-15HL type on a magnetic body, such as iron, the enclosed aluminum sheet or any other aluminum sheet having a minimum size of 30 x 30 x t 0.3 mm 1.181 x 1.181 x t 0.012 in, should be inserted between the sensor and the magnetic body.
However, it is not necessary to use the aluminum sheet when mounting on a non-magnetic body, such as, aluminum or an insulator.
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
4) The flexible cable type (model No. with suffix "-R") has a 0.15 mm2 (GXL-8 type: 0.1 mm2) flexible, oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long.

^ Back to top

PNP output types

Type GXL-N12 type GXL-15 type
Cable type Terminal type Standard
Front sensing Front sensing
Standard Model No. GXL-N12F-P GXL-N12FT-P GXL-15F-P
Max. operation distance (Note 2) 3 mm 0.118 in ± 10% 5 mm 0.197 in ± 10%
Stable sensing range (Note 2) 0 to 2 mm
0 to 0.079 in
0 to 4 mm
0 to 0.157 in
Standard sensing object Iron sheet 20 x 20 x t 1 mm
0.787 x 0.787 x t 0.039 in
Hysteresis 20 % or less of operation distance
(with standard sensing object)
Repeatability Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.002 in or less
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption 15 mA or less
Output PNP open-collector transistor
・Maximum source current: 100 mA
・Applied voltage: 30 V DC or less
(between output and +V)
・Residual voltage:
1 V or less (at 100 mA source current)
0.4 V or less (at 16 mA source current)
Utilization category DC-12 or DC-13
Short-circuit protection -
Max. response frequency 500 Hz 250 Hz
Operation indicator Red LED (lights up when the output is ON)
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC), IP67 g (JEM) except for the terminal type
Ambient temperature -10 to +55 ℃ 14 to +131 ℉,
Storage: -30 to +80 ℃ -22 to +176 ℉
Ambient humidity 45 to 85 % RH, Storage: 35 to 95 % RH
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X,
Y and Z directions for two hours each
Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X,
Y and Z directions for three times each
Sensing
range
variation
Temperature characteristics Over ambient temperature range -10 to +55 ℃ +14 to +131 ℉
: Within +15/ -10 % of sensing range at +20 ℃ +68 ℉
Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage
Material Enclosure: PBT
Indicator part: Polyalylate
Cable (Note 3) 0.15 mm2 3-core oil, heat and cold resistant
cabtyre cable, 1 m 3.281 ft long
- 0.15 mm2 3- core oil,
heat and cold resistant
cabtyre cable,
1 m 3.281 ft long
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight 20 g approx. 5 g approx. 20 g approx.
Accessories MS-GXL12-1 (Sensor mounting bracket): 1 pc.
M3 pan head screw, plain washer,
spring washer and nut: 1 set
MS-R1 (Rubber washer): 1 pc.
-

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
3) The flexible cable type (model No. with suffix "-R") has a 0.15 mm2 (GXL-8 type: 0.1 mm2) flexible, oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long.

^ Back to top

 

Panasonic Electric Works Corporation of America Contact Print