GL-N12 Proximity Sensors Specifications
Specifications for this product appear below.
| Type | Boss type (Note 2) | ||||
|---|---|---|---|---|---|
| NPN output | |||||
| Standard | Different frequency | ||||
| Model No. | Front sensing | GL- N12Fx10 (Note 2) | GL- N12FBx10 | GL- N12FIx10 | GL- N12FIBx10 |
| Top sensing | GL- N12Hx10 | GL- N12HBx10 | GL- N12HIx10 | GL- N12HIBx10 |
|
| Max. operation distance (Note 3) | 4 ± 0.5 mm 0.157 ± 0.020 in | ||||
| Stable sensing range (Note 3) | 0 to 3 mm 0 to 0.118 in | ||||
| Standard sensing object | Iron sheet 20 x 20 x t 1 mm 0.787 x 0.787 x t 0.039 in |
||||
| Hysteresis | 20 % or less of operation distance (with standard sensing object) |
||||
| Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | ||||
| Current consumption | 10 mA or less | ||||
| Output | NPN open-collector transistor - Maximum sink current: 100 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) |
||||
| Utilization category | DC-12 or DC-13 | ||||
| Output operation | Normally open | Normally closed | Normally open | Normally closed | |
| Max. response frequency | 1.3kHz | ||||
| Operation indicator | Orange LED (lights up when the output is ON) | ||||
| Pollution degree | 3 (Industrial environment) | ||||
| Protection | IP67 (IEC) | ||||
| Ambient temperature | -10 to +55 ℃ +14 to +131 ℉, Storage: -25 to +70 ℃ -13 to +158 ℉ |
||||
| Ambient humidity | 45 to 85 % RH, Storage: 35 to 95 % RH | ||||
| EMC | EN 60947-5-2 | ||||
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||||
| Insulation resistance | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | ||||
| Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each | ||||
| Shock resistance | 1,000 m/s2 (100 G approx.) acceleration in X, Y and Z directions for three times each | ||||
| Sensing range variation | Temperature characteristics | Over ambient temperature range -10 to +55 ℃ +14 to +131 ℉ : Within +15 /-10 % of sensing range at +20 ℃ +68 ℉ |
|||
| Voltage characteristics | Within ±2 % for ±10 % fluctuation of the supply voltage | ||||
| Material | Enclosure: Polyalylate | ||||
| Cable | 0.18 mm2 3-core cabtyre cable, 1 m 3.281 ft long | ||||
| Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | ||||
| Weight | Net weight : 20g approx. | ||||
| Type | Boss type (Note 2) | ||||
|---|---|---|---|---|---|
| PNP output | |||||
| Standard | Different frequency | ||||
| Model No. | Front sensing | GL- N12F- Px10 | GL- N12FB- Px10 | GL- N12FI- Px10 | GL- N12FIB- Px10 |
| Top sensing | GL- N12H- Px10 | GL- N12HB- Px10 | GL- N12HI- Px10 | GL- N12HIB- Px10 |
|
| Max. operation distance (Note 3) | 4 ± 0.5 mm 0.157 ± 0.020 in | ||||
| Stable sensing range (Note 3) | 0 to 3 mm 0 to 0.118 in | ||||
| Standard sensing object | Iron sheet 20 x 20 x t 1 mm 0.787 x 0.787 x t 0.039 in |
||||
| Hysteresis | 20 % or less of operation distance (with standard sensing object) |
||||
| Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | ||||
| Current consumption | 15 mA or less | ||||
| Output | PNP open-collector transistor - Maximum source current: 100 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1 V or less (at 100 mA source current) 0.4 V or less (at 16 mA source current) |
||||
| Utilization category | DC-12 or DC-13 | ||||
| Output operation | Normally open | Normally closed | Normally open | Normally closed | |
| Max. response frequency | 1.3kHz | ||||
| Operation indicator | Orange LED (lights up when the output is ON) | ||||
| Pollution degree | 3 (Industrial environment) | ||||
| Protection | IP67 (IEC) | ||||
| Ambient temperature | -10 to +55 ℃ +14 to +131 ℉, Storage: -25 to +70 ℃ -13 to +158 ℉ |
||||
| Ambient humidity | 45 to 85 % RH, Storage: 35 to 95 % RH | ||||
| EMC | EN 60947-5-2 | ||||
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||||
| Insulation resistance | 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | ||||
| Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each | ||||
| Shock resistance | 1,000 m/s2 (100 G approx.) acceleration in X, Y and Z directions for three times each | ||||
| Sensing range variation | Temperature characteristics | Over ambient temperature range -10 to +55 ℃ +14 to +131 ℉ : Within +15 -10 % of sensing range at +20 ℃ +68 ℉ |
|||
| Voltage characteristics | Within ±2 % for ±10 % fluctuation of the supply voltage | ||||
| Material | Enclosure: Polyalylate | ||||
| Cable | 0.18 mm2 3-core cabtyre cable, 1 m 3.281 ft long |
||||
| Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | ||||
| Weight | Net weight : 20g approx. | ||||
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2) The without boss type (GL-12F type) is also available.
The specifications are the same as for the with boss type. (However, max. response frequency: 500 Hz, operation indicator: Red LED)
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.