Type DC 3-wire (NPN output)
Front sensing Top sensing
Model No. GL-
8Fx10
GL-
8FBx10
GL-
8Hx10
GL-
8HBx10
Different frequency GL-
8FIx10
GL-
8FIBx10
GL-
8HIx10
GL-
8HIBx10
Max. operation distance (Note 2) 2.5 mm 0.098 in ± 20 %
Stable sensing range (Note 2) 0 to 1.8 mm 0 to 0.071 in
Standard sensing object Iron sheet 15 x 15 x t 1 mm
0.591 x 0.591 x t 0.039 in
Hysteresis 20 % or less of operation distance
(with standard sensing object)
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption 15 mA or less
Output NPN open-collector transistor
- Maximum sink current: 100 mA (Note 4)
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
  Utilization category DC-12 or DC-13
Output operation Normally open Normally closed Normally open Normally closed
Short-circuit protection Incorporated
Max. response frequency 1kHz
Operation indicator Orange LED (lights up when the output is ON)
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC)
Ambient temperature -25 to +70 ℃ -13 to +158 ℉,
Storage: -30 to +80 ℃ -22 to +176 ℉
Ambient humidity 35 to 95 % RH, Storage: 35 to 95 % RH
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Sensing
range
variation
Temperature characteristics Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉
: within +10 /-15 % of sensing range at +20 ℃ +68 ℉
Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage
Material Enclosure: Polyalylate
Cable 0.15 mm2 3-core cabtyre cable, 1 m 3.281 ft long
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Weight Net weight : 13 g approx.

^ Back to top

Type DC 2-wire type
Front sensing Top sensing
Model No.   GL-
8FUx10
GL-
8FUBx10
GL-
8HUx10
GL-
8HUBx10
Different frequency GL-
8FUIx10
GL-
8FUIBx10
GL-
8HUIx10
GL-
8HUIBx10
Max. operation distance (Note 2) 2.5 mm 0.098 in ± 20 %
Stable sensing range (Note 2) 0 to 1.8 mm 0 to 0.071 in
Standard sensing object Iron sheet 15 x 15 x t 1 mm
0.591 x 0.591 x t 0.039 in
Hysteresis 20 % or less of operation distance
(with standard sensing object)
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption 0.8 mA or less (Note 3)
Output Non-contact DC 2-wire type
- Load current: 3 to 70 mA (Note 5)
- Residual voltage: 3 V or less (Note 6)
  Utilization category DC-12 or DC-13
Output operation Normally open Normally closed Normally open Normally closed
Short-circuit protection Incorporated
Max. response frequency 1kHz
Operation indicator Orange LED (lights up when the output is ON)
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC)
Ambient temperature -25 to +70 ℃ -13 to +158 ℉,
Storage: -30 to +80 ℃ -22 to +176 ℉
Ambient humidity 35 to 95 % RH, Storage: 35 to 95 % RH
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Sensing
range
variation
Temperature characteristics Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉
: within +10 -15 % of sensing range at +20 ℃ +68 ℉
Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage
Material Enclosure: Polyalylate
Cable 0.15 mm2 2-core cabtyre cable, 1 m 3.281 ft long
Cable extension Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Weight Net weight : 12 g approx.

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.
3) It is the leakage current when the output is in the OFF state.
4) When the ambient temperature is +60 to +70 ℃ +140 to +158 ℉, the maximum sink current varies depending on the ambient humidity.
5) The maximum load current varies depending on the ambient temperature.
6) When the cable is extended, the residual voltage becomes larger according to the resistance of the cable.

^ Back to top