Type Standard
Different frequency
Model No. GL-18H GL-18HI GL-18HB
Max. operation distance (Note 2) 5 mm 0.197 in ± 10 %
Stable sensing range
(Note 2)
0 to 4 mm 0 to 0.157 in
Standard sensing object Iron sheet 25 x 25 x t 1 mm
0.984 x 0.984 x t 0.039 in
Hysteresis 15 % or less of operation distance
(with standard sensing object)
Supply voltage 10 to 30 V DC Ripple P-P 10 % or less
Current consumption 10 mA or less
Output NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
Utilization category DC-12 or DC-13
Output operation Normally open Normally closed
Max. response frequency 1kHz
Operation indicator Red LED (lights up when the output is ON)
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC), IP67g (JEM)
Ambient temperature -25 to +70 ℃ -13 to +158 ℉,
Storage: -25 to +70 ℃ -13 to +158 ℉
Ambient humidity 45 to 85 % RH, Storage: 45 to 85 % RH
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Sensing
range
variation
Temperature characteristics Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉
: within ±10 % of sensing range at +20 ℃ +68 ℉
Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage
Material Enclosure: Polyalylate
Cable 0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Weight Net weight : 45 g approx.
Accessory -

^ Back to top

Type Long sensing range
Different frequency
Model No. GL-18HL GL-18HLI GL-18HLB
Max. operation distance
(Note 2)
12 mm 0.472 in ± 10 %
Stable sensing range
(Note 2)
0 to 10 mm 0 to 0.394 in
Standard sensing object Iron sheet 40 x 40 x t 1 mm
1.575 x 1.575 x t 0.039 in
Hysteresis 15 % or less of operation distance
(with standard sensing object)
Supply voltage 10 to 30 V DC Ripple P-P 10 % or less
Current consumption 10 mA or less
Output NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1.5 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
Utilization category DC-12 or DC-13
Output operation Normally open Normally closed
Max. response frequency 500Hz
Operation indicator Red LED (lights up when the output is ON)
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC), IP67g (JEM)
Ambient temperature -25 to +70 ℃ -13 to +158 ℉,
Storage: -25 to +70 ℃ -13 to +158 ℉
Ambient humidity 45 to 85 % RH, Storage: 45 to 85 % RH
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Sensing
range
variation
Temperature characteristics Over ambient temperature range -25 to +70 ℃ -13 to +158 ℉
: within ±10 % of sensing range at +20 ℃ +68 ℉
Voltage characteristics Within ±2 % for ±10 % fluctuation of the supply voltage
Material Enclosure: Polyalylate
Cable 0.3 mm2 3-core oil resistant cabtyre cable, 1 m 3.281 ft long
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Weight Net weight : 45 g approx.
Accessory MS-GL18HL (Sensor mounting bracket): 1 set

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation.