DPC/DPH-100 Pressure/Flow Sensors Specifications
Specifications for this product appear below.
Sensor heads
| Type | Compound pressure | Positive pressure | Vacuum pressure | ||||||
|---|---|---|---|---|---|---|---|---|---|
| ±100 kPa type | 1 MPa type | -101 kPa type | |||||||
| Model No.(Note 3) | DPH-101 (-R) | DPH-101-M3 (-R) | DPH-101-M5 (-R) | DPH-102 | DPH-102-M5 (-R) | DPH-103 (-R) | DPH-103-M3 (-R) | DPH-103-M5 (-R) |
|
| Type of pressure | Gauge pressure | ||||||||
| Rated pressure range | -100.0 to +100.0 kPa | 0 to +1.000 MPa | 0 to -101.0 kPa | ||||||
| Pressure withstandability | 500 kPa | 1.5 MPa | 500 kPa | ||||||
| Applicable fluid | Air, non-corrosive gas | ||||||||
| Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | ||||||||
| Current consumption | 15 mA or less | ||||||||
| Analog voltage output | Output voltage: 1 to 5 V (over rated pressure range) Zero point: within 1 V ± 2.5 % F.S. (vacuum / positive pressure type) within 3 V ± 3 % F.S. (compound pressure type) Span: within 4 V ± 3.5 % F.S. Linearity: within ±0.5 % F.S. Output impedance: 1 kΩ approx. |
||||||||
| Protection | IP40 (IEC) | ||||||||
| Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | ||||||||
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||||||
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||||||||
| Insulation resistance | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | ||||||||
| Vibration resistance | 10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each | ||||||||
| Shock resistance | 1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each | ||||||||
| Temperature characteristics | Over ambient temperature range 0 to +50 ℃ +32 to +122 ℉: within ±2 % F.S. of detected pressure at +25 ℃ +77 ℉ | ||||||||
| Pressure port | DPH-10□(-R): R1/8 male thread + M5 female thread, DPH-10□-M3(-R): M3 male thread (for installing gasket) DPH-10□-M5(-R): M5 male thread (for installing gasket) |
||||||||
| Material | Front case: PBT, Rear case: PBT (glass fiber reinforced), Pressure port: Stainless steel (SUS303), O-ring: NBR Pressure element: Silicon diaphragm, PPS |
||||||||
| Connecting method | Connector | ||||||||
| Cable | 0.2 mm2 4-core oil resistant cabtyre cable (Models with "-R" affixed to the Model No. have flexible, oil-resistant cabtyre cable) | ||||||||
| Cable extension | Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable. | ||||||||
| Weight | Net weight | DPH-10□(-R): Head 10 g approx. / Cable 40 g approx., DPH-10□-M3/M5(-R): Head 6 g approx. / Cable 40 g approx. | |||||||
| Gross weight | DPH-10□(-R): 80 g approx., DPH-10□-M3/M5(-R): 70 g approx. | ||||||||
| Accessory | Connector (e-CON): 1 pc. | ||||||||
Notes:
1) Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +25 ℃ +77 ℉.
2) The sensor head can be used independently.
3) Model No. having the suffix "-R" is flexible cable type.
Controllers
| Type | NPN output type | PNP output type | |
|---|---|---|---|
| Model No. | DPC-101 | DPC-101-P | |
| Applicable sensor head | DPH-101□, DPH-102□, DPH-103□ | ||
| Rated pressure range (Note 2) |
Compound pressure: -100.0 to +100.0 kPa, Positive pressure: 0 to +1.000 MPa, Vacuum pressure: 0 to -101.0 kPa |
||
| Set pressure range (Note 2) |
Compound pressure: -199.9 to +199.9 kPa (-1.999 to +1.999 kgf/cm2, -19.98 to +19.98 psi, -1.999 to +1.999 bar, -1510 to +1537 mmHg, -59.4 to +60.5 inHg) Positive pressure: -1.050 to +1.050 MPa (-10.71 to +10.71 kgf/cm2, -152.2 to +152.2 psi, -10.50 to +10.50 bar) Vacuum pressure: +101.3 to -101.3 kPa (+1.033 to -1.033 kgf/cm2, +14.70 to -14.70 psi, +1.013 to -1.013 bar, +760 to -760 mmHg, +29.9 to -29.9 inHg) |
||
| Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | ||
| Power consumption | Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD): 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL): 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current |
||
| Sensor head supply voltage | Same as supply voltage | ||
| Comparative outputs (Comparative output 1, 2) |
NPN open-collector transistor (2 outputs) ・Maximum sink current: 100 mA ・Applied voltage: 30 V DC or less (between comparative output and 0 V) ・Residual voltage: 1 V or less (at 100 mA sink current) |
PNP open-collector transistor (2 outputs) ・Maximum source current: 100 mA ・Applied voltage: 30 V DC or less (between comparative output and +V) ・Residual voltage: 1 V or less (at 100 mA source current) |
|
| Output operation | NO / NC, selectable by key operation | ||
| Output modes | EASY mode / Hysteresis mode / Window comparator mode | ||
| Hysteresis | Minimum 1 digit (variable) (however, 2 digits when using psi unit) | ||
| Repeatability | With vacuum / positive pressure type connected: within ±0.2 % F.S. (±2 digits) With compound pressure type connected: within ±0.2 % F.S. (±4 digits) |
||
| Response time | 0.5 ms, 1 ms, 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation | ||
| Short-circuit protection | Incorporated | ||
| Analog output | <Analog voltage output> ・Output current: 1 to 5 V DC ・Zero point: within 1 V ± 0.5 % F.S. (vacuum / positive pressure type) within 3 V ± 0.5 % F.S. (compound pressure type) ・Span: within 4 V ± 0.5 % F.S. ・Linearity: within ±0.1 % F.S. ・Output impedance: 1 kΩ approx. <Analog current output> ・Output current: 4 to 20 mA ・Zero point: within 4 mA ± 1 % F.S. (vacuum / positive pressure type) within 12 mA ± 1.5 % F.S. (compound pressure type) ・Span: within 16 mA ± 1.5 % F.S. ・Linearity: within ±0.1 % F.S. ・Load resistance: 250 Ω (max.). |
||
| Inputs | Sensor head input | Input voltage range: 1 to 5 V DC (over rated pressure range) | |
| External input (Auto-reference function/Remote zero-adjustment function) |
ON voltage: +0.4 V DC or less OFF voltage: +5 to +30 V DC, or open Input impedance: 10 kΩ approx. Input time: 1 ms or more |
ON voltage: +5 V to +V DC OFF voltage: +0.6 V DC or less, or open Input impedance: 10 kΩ approx. Input time: 1 ms or more |
|
| Display | 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) | ||
| Displayable pressure range | Vacuum pressure: +5.1 to -101.3 kPa, Positive pressure: -0.050 to +1.020 MPa, Compound pressure: -101.3 to +105.0 kPa |
||
| Operation indicator | Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator: Lights up when each comparative output is ON) | ||
| Protection | IP40 (IEC) | ||
| Ambient temperature | -10 to +50 ℃ +14 to +122 ℉ (No dew condensation or icing allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ | ||
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||
| Insulation resistance | 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | ||
| Vibration resistance | 10 to 500 Hz frequency, amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted : 10 to 150 Hz frequency, amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) | ||
| Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each | ||
| Temperature characteristics | Within ±0.5 % F.S. (ambient temperature range based on +20 ℃ +68 ℉) | ||
| Material | Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber | ||
| Connecting method | Connector | ||
| Cable length | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | ||
| Weight | Net weight: 25 g approx. (excluding connector attached cable), Gross weight: 140 g approx. | ||
| Accessories | CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label: 1 set | ||
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) It changes automatically according to the connected pressure sensor head.
3) The values specified above are applied only to the controller.