DP-100 Pressure/Flow Sensors Specifications

Pressure/Flow Sensors DP-100

Specifications for this product appear below.

Type Standard Multi-function
For low pressure For high pressure For low pressure For high pressure
Model No. Asia (Note 2) DP-101
(-M)(-P)
DP-102
(-M)(-P)
DP-101A
(-M)(-P)
DP-102A
(-M)(-P)
Europe DP-101
-E-P
DP-102
-E-P
DP-101A
-E-P
DP-102A
-E-P
M8 plug-in connector type DP-111
-E-P-J
DP-112
-E-P-J
DP-111A
-E-P-J
DP-112A
-E-P-J
North America (Note 2) DP-101
-N(-P)
DP-102
-N(-P)
DP-101A
-N(-P)
DP-102A
-N(-P)
Type of pressure Gauge pressure
Rated pressure range -100.0 to +100.0 kPa -0.100 to +1.000 MPa -100.0 to +100.0 kPa -0.100 to +1.000 MPa
Set pressure range -100.0 to +100.0 kPa
(-1.020 to +1.020 kgf/cm2
-1.000 to +1.000 bar
-14.50 to +14.50 psi
-750 to +750 mmHg
-29.5 to +29.5 inHg)
-0.100 to +1.000 MPa
(-100 to +1,000 kPa
-1.02 to +10.20 kgf/cm2
-1.00 to +10.00 bar
-14.6 to +145.0 psi)
-100.0 to +100.0 kPa
(-1.020 to +1.020 kgf/cm2
-1.000 to +1.000 bar
-14.50 to +14.50 psi
-750 to +750 mmHg
-29.5 to +29.5 inHg)
-0.100 to +1.000 MPa
(-100 to +1,000 kPa
-1.02 to +10.20 kgf/cm2
-1.00 to +10.00 bar
-14.6 to +145.0 psi)
Pressure withstandability 500 kPa 1.5 MPa 500 kPa 1.5 MPa
Applicable fluid Non-corrosive gas
Selectable unit For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Power consumption Normal operation: 840 mW or less
(Current consumption 35 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less at STD
(Current consumption 25 mA or less at 24 V supply voltage)
480 mW or less at FULL
(Current consumption 20 mA or less at 24 V supply voltage)
Comparative output
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less (between comparative output and 0 V)
・Residual voltage: 2 V or less (at 100 mA sink current)

PNP open-collector transistor
・Maximum source current: 100 mA
・Applied voltage: 30 V DC or less (between comparative output and +V)
・Residual voltage: 2 V or less (at 100 mA source current)
Output operation / Output modes NO / NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode
Hysteresis Minimum 1 digit (variable)
(however, 2 digits when using psi unit)
Repeatability ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits) ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits)
Response time 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Short-circuit protection Incorporated
External input
(Auto-reference function /
Remote zero-adjustment
function)
-
ON voltage: 0.4 V DC or less
OFF voltage: 5 to 30 V DC, or open
Input impedance: 10 kΩ approx.
Input time: 1 ms or more

ON voltage: 5 V to +V DC
OFF voltage: 0.6 V DC or less, or open
Input impedance: 10 kΩ approx.
Input time: 1 ms or more
Analog voltage output - Output voltage: 1 to 5 V DC
Zero point: within 3 V ± 5 % F.S.
Span: within 4 V ± 5 % F.S.
Linearity: within ±1 % F.S.
Output impedance: 1 kΩ approx.
Zero point: within 1 V ± 5 % F.S.
Span: within 4.4 V ± 5 % F.S.
Linearity: within ±1 % F.S.
Output impedance: 1 kΩ approx.
Display 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Displayable pressure
range
-100.0 to +100.0 kPa
(-1.020 to +1.020 kgf/cm2
-1.000 to +1.000 bar
-14.50 to +14.50 psi
-750 to +750 mmHg
-29.5 to +29.5 inHg)
-0.100 to +1.000 MPa
(-100 to +1,000 kPa
-1.02 to +10.20 kgf/cm2
-1.00 to +10.00 bar
-14.6 to +145.0 psi)
-100.0 to +100.0 kPa
(-1.020 to +1.020 kgf/cm2
-1.000 to +1.000 bar
-14.50 to +14.50 psi
-750 to +750 mmHg
-29.5 to +29.5 inHg)
-0.100 to +1.000 MPa
(-100 to +1,000 kPa
-1.02 to +10.20 kgf/cm2
-1.00 to +10.00 bar
-14.6 to +145.0 psi)
Indicator Orange LED
(Comparative output 1 operation indicator, comparative output 2 operation indicator:
Lights up when each comparative output is ON)
Orange LED
(Comparative output 1 operation indicator: Lights up when comparative output is ON,
Analog voltage output operation indicator: Lights up when setting)
Protection IP40 (IEC)
Ambient temperature -10 to +50 ℃ +14 to +122 ℉,
Storage: -10 to +60 ℃ +14 to +140 ℉
(No dew condensation or icing allowed)
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min.
between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, 3 mm 0.118 in amplitude, in X, Y and Z directions for two hours each
(when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude, in X, Y and Z directions for two hours each)
Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each
Temperature characteristics Within ±0.5 % F.S. (at +20 ℃ +68 ℉) Within ±1 % F.S. (at +20 ℃ +68 ℉) Within ±0.5 % F.S. (at +20 ℃ +68 ℉) Within ±1 % F.S. (at +20 ℃ +68 ℉)
Pressure port Asia: M5 female thread + R (PT) 1/8 male thread [excluding DP-10□-M(-P)], Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread
Material Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Brass (nickel plated)[DP-□-M(-P), DP-□-J: Stainless steel (SUS)] , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connecting method / Cable length Connector / Total length up to 100 m 328.084 ft (less than 10 m 32.808 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable.
Weight Net weight: 40 g approx. [DP-10□-M(-P): 30 g approx.], Gross weight: 135 g approx. [DP-10□-M(-P): 125 g approx.]
Accessories CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (Excluding M8 plug-in connector type)

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Model Nos. of Asia type having "-M" are short pressure port type. Model Nos. of North America type having the suffix "-P" are PNP output type.

^ Back to top

Panasonic Electric Works Corporation of America Contact Print