NX5 Photoelectric Sensors Specifications
Specifications for this product appear below.
| Type | Thru-beam | ||||
|---|---|---|---|---|---|
| Long sensing range | |||||
| Model No. | NX5-M10RA | NX5-M10RB | NX5-M30A | NX5-M30B | |
| Sensing range | 10 m 32.808 ft | 30 m 98.425 ft | |||
| Sensing object | ø20 mm ø0.787 in or more opaque object (Note 4) | ø20 mm ø0.787 in or more opaque object (Completely beam interrupted object) (Note 4) |
|||
| Hysteresis | - | ||||
| Repeatability (perpendicular to sensing axis) |
0.1 mm 0.004 in or less | 0.2 mm 0.008 in or less | |||
| Supply voltage | 24 to 240 V AC +10 /-15 % or 12 to 240 V DC +10 /-15 % Ripple P-P 10 % or less | ||||
| Power consumption | Emitter: 1 VA or less Receiver: 2 VA or less |
Emitter: 1.5 VA or less Receiver: 2 VA or less |
|||
| Output | Relay contact 1 c ・Switching capacity: 250 V AC 1 A (resistive load) 30 V DC 2 A (resistive load) ・Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour) 100,000 or more switching operations (switching frequency 3,600 operations/hour) ・Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
||||
| Output operation |
Light-ON | Dark-ON | Light-ON | Dark-ON | |
| Response time | 10 ms or less | ||||
| Operation indicator | Red LED (lights up when the output is ON) | ||||
| Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) |
||||
| Power indicator | - | Red LED (lights up when the power is ON) |
|||
| Sensitivity adjuster | Continuously variable adjuster | - | |||
| Automatic interference prevention function |
(Use optional interference prevention filters) |
- | |||
| Pollution degree | 3 (Industrial environment) | ||||
| Protection | IP66 (IEC) | ||||
| Ambient temperature | -20 to +55 ℃ - 4 to +131 ℉ (No dew condensation or icing allowed) (Note 6), Storage: -30 to +70 ℃ -22 to +158 ℉ |
||||
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
| Ambient illuminance | Incandescent light: 3,500 lx at the light-receiving face | ||||
| EMC | EN 61000-6-2, EN 61000-6-4 | ||||
| Voltage withstandability | 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | ||||
| Insulation resistance | 20 MΩ, or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | ||||
| Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each | ||||
| Shock resistance | 500 m/s2 (50 G approx.) in X, Y and Z directions for three times each | ||||
| Emitting element | Red LED (modulated) | Infrared LED (modulated) | |||
| Peak emission wavelength | 660 nm 0.026 mil | 880 nm 0.035 mil | |||
| Material | Enclosure: Polycarbonate, Lens: Polycarbonate, Cover: Polycarbonate, Front cover (retroreflective type sensor only): Acrylic | ||||
| Cable | 0.3 mm2 5-core (thru-beam type emitter: 2-core) cabtyre cable, 2 m 6.562 ft long | ||||
| Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver). | ||||
| Net weight | Emitter: 100 g approx. Receiver: 140 g approx. |
Emitter: 125 g approx. Receiver: 140 g approx. |
|||
| Accessories | Adjusting screwdriver: 1 pc. | - | |||
| Type | Retroreflective | Diffuse reflective | |||||
|---|---|---|---|---|---|---|---|
| With polarizing filters | Long sensing range | ||||||
| Model No. | NX5- PRVM 5A | NX5- PRVM 5B | NX5- RM 7A | NX5- RM 7B | NX5- D 700A | NX5- D 700B |
|
| Sensing range | 0.1 to 5 m 0.328 to 16.404 ft (Note 2) | 0.1 to 7 m 0.328 to 22.966 ft (Note 2) | 700 mm 27.559 in (Note 3) | ||||
| Sensing object | ø50 mm ø1.969 in or more opaque, translucent or specular object (Note 2, 5) |
ø50 mm ø1.969 in or more opaque or translucent object (Note 2, 5) | Opaque, translucent or transparent object (Note 5) |
||||
| Hysteresis | - | 15 % or less of operation distance (Note 3) | |||||
| Repeatability (perpendicular to sensing axis) |
0.2 mm 0.008 in or less | 0.3 mm 0.012 in or less | |||||
| Supply voltage | 24 to 240 V AC +10 /-15 % or 12 to 240 V DC +10 /-15 % Ripple P-P 10 % or less | ||||||
| Power consumption | 2 VA or less | ||||||
| Output | Relay contact 1 c ・Switching capacity: 250 V AC 1 A (resistive load) 30 V DC 2 A (resistive load) ・Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour) 100,000 or more switching operations (switching frequency 3,600 operations/hour) ・Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
||||||
| Output operation |
Light -ON |
Dark -ON |
Light -ON |
Dark -ON |
Light -ON |
Dark -ON |
|
| Response time | 10 ms or less | ||||||
| Operation indicator | Red LED (lights up when the output is ON) | ||||||
| Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) |
||||||
| Power indicator | - | ||||||
| Sensitivity adjuster | Continuously variable adjuster | - | Continuously variable adjuster | ||||
| Automatic interference prevention function |
Incorporated (Two units of sensors can be mounted close together.) |
||||||
| Pollution degree | 3 (Industrial environment) | ||||||
| Protection | IP66 (IEC) | ||||||
| Ambient temperature | -20 to +55 ℃ - 4 to +131 ℉ (No dew condensation or icing allowed) (Note 6), Storage: -30 to +70 ℃ -22 to +158 ℉ |
||||||
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||||
| Ambient illuminance | Incandescent light: 3,500 lx at the light-receiving face | ||||||
| EMC | EN 61000-6-2, EN 61000-6-4 | ||||||
| Voltage withstandability | 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals | ||||||
| Insulation resistance | 20 MΩ, or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | ||||||
| Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each | ||||||
| Shock resistance | 500 m/s2 (50 G approx.) in X, Y and Z directions for three times each | ||||||
| Emitting element | Red LED (modulated) | Infrared LED (modulated) | |||||
| Peak emission wavelength | 660 nm 0.026 mil | 880 nm 0.035 mil | |||||
| Material | Enclosure: Polycarbonate, Lens: Polycarbonate, Cover: Polycarbonate, Front cover (retroreflective type sensor only): Acrylic | ||||||
| Cable | 0.3 mm2 5-core (thru-beam type emitter: 2-core) cabtyre cable, 2 m 6.562 ft long | ||||||
| Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver). | ||||||
| Net weight | 140 g approx. | ||||||
| Accessories | RF-230 (Reflector): 1 pc. Adjusting screwdriver: 1 pc. |
RF-230 (Reflector): 1 pc. | Adjusting screwdriver: 1 pc. | ||||
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2) The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector.
The sensor can detect an object less than 0.1 m 0.328 ft away.
3) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object.
4) If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected.
5) Make sure to confirm detection with an actual sensor before use.
6) In case the sensor is to be used at an ambient temperature of -15℃ +5℉, or less, please contact our office.