HL-T1 Measurement Sensors Specifications
Specifications for this product appear below.
Sensor heads
| Type | Beam diameter ø1 mm ø0.039 in type | Sensing width 5 mm 0.197 in type | Sensing width 10 mm 0.394 in type | ||
|---|---|---|---|---|---|
| Model No. | IEC / JIS standards conforming type | HL-T1001A | HL-T1005A | HL-T1010A | |
| FDA regulations conforming type | HL-T1001F | HL-T1005F | HL-T1010F | ||
| Applicable controller | HL-AC1, HL-AC1P | ||||
| Sensing range | 0 to 500 mm 0 to 19.685 in | 500 to 2,000 mm 19.685 to 78.74 in | 500 mm 19.685 in | ||
| Sensing width | ø1 mm ø0.039 in | ø1 to ø2.5 mm ø0.039 to ø0.098 in | 5 mm 0.197 in | 10 mm 0.394 in | |
| Min. sensing object | ø8 μm ø0.315 mil opaque object |
ø50 μm ø1.969 mil opaque object |
ø0.05 mm ø0.002 in opaque object | ø0.1 mm ø0.004 in opaque object | |
| Repeatability (During the state in which light is half blocked) |
4 μm 0.157 mil (Note 2) |
- | 4 μm 0.157 mil (Note 2) | ||
| Linear output resolution (Note 3) |
4 μm 0.157 mil (Note 2, 4) |
- | 4 μm 0.157 mil (Note 2) | ||
| Emission indicator | Green LED (lights up during laser emission) | ||||
| Interference prevention function | Two units of sensors can be mounted close together. (When the controller interference prevention function is used) | ||||
| Pollution degree | 3 (industrial environment) | ||||
| Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: -25 to +70 ℃ -13 to +158 ℉ | ||||
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
| Ambient illuminance | Incandescent light: 10,000 lx at the light-receiving face | ||||
| EMC | EN 61000-6-2, EN 61000-6-4 | ||||
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||||
| Insulation resistance | 100 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure | ||||
| Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each | ||||
| Shock resistance | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each | ||||
| Emitting element | IEC / JIS standards conforming type |
Red semiconductor laser Class 1 (IEC / JIS) (modulated, max. output: 0.2 mW, peak emission wavelength: 650 nm 0.026 mil) |
Red semiconductor laser Class 1 (IEC / JIS) (modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil) |
||
| FDA regulations conforming type |
Red semiconductor laser Class II (FDA) (modulated, max. output: 0.2 mW, peak emission wavelength: 650 nm 0.026 mil (IEC / JIS: Class 1)) |
Red semiconductor laser Class II (FDA) (modulated, max. output: 0.35 mW, peak emission wavelength: 650 nm 0.026 mil (IEC / JIS: Class 1)) |
|||
| Material | Enclosure: Polyetherimide, Case cover: Polycarbonate, Front cover: Glass | ||||
| Cable | 0.09mm2 3-core shielded cable with connector, 0.5 m 1.640 ft long | ||||
| Cable extension | Extension up to total 10 m 32.808 ft is possible, with the optional cable. | ||||
| Net weight | Emitter: 15 g approx., Receiver: 15 g approx. | Emitter: 30 g approx., Receiver: 20 g approx. | |||
| Accessories | MS-HLT1-1 (Sensor head mounting bracket): One set of two brackets for both the emitter and the receiver CN-HLT1-1 (Sensor head to controller connection cable): 1 cable Laser beam alignment sticker: 2 pcs. Label set (FDA regulations conforming type only): 1 set |
MS-LA3-1 (Sensor head mounting bracket): One set of two brackets for both the emitter and the receiver CN-HLT1-1 (Sensor head to controller connection cable): 1 cable Laser beam alignment sticker: 2 pcs. Label set (FDA regulations conforming type only): 1 set |
|||
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) In case of an average sampling rate of 64 times.
3) Value calculated with the linear output allowance factor (±3 σ) when connected to the controller included in the calculation of the detection width.
4) This value was obtained by converting the range of linear output fluctuation (±3 σ) into a sensing width, assuming that the smallest sensing object blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.
Calculation unit
| Model No. | HL-AC1-CL | |
|---|---|---|
| Connected controller | HL-AC1, HL-AC1P | |
| Current consumption | 12 mA or less (supplied from the controller) | |
| Connecting method | Connector | |
| Connection indicator | Orange LED (lights up when connected to the controller) |
|
| Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: -15 to +60 ℃ +5 to +140 ℉ |
|
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | |
| Voltage withstandablity | 1,000 V AC for one min. between all supply terminals connected together and enclosure | |
| Insulation resistance | 100 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | |
| Vibration resistance | 10 to 150 Hz frequency, 0.7 mm 0.028 in amplitude in X, Y and Z directions for 80 min. | |
| Shock resistance | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each | |
| Material | Enclosure: ABS, Indicator part: Acrylic | |
| Weight | Net weight: 50 g approx. | |
Note:
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
Controllers
| Type | NPN output | PNP output | |
|---|---|---|---|
| Model No. | HL-AC1 | HL-AC1P | |
| Applicable sensor head | HL-T1001A/T1001F, HL-T1005A/T1005F, HL-T1010A/T1010F | ||
| Supply voltage / Current consumption | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less / 190 mA or less (when connected to the sensor head) | ||
| Measuring cycle | 150 μs | ||
| Linear output | Current / voltage output switchable (Note 2) ・During current output: 4 to 20 mA/F.S., Maximum load resistance: 300 Ω ・During voltage output: ±4 V/F.S., Output impedance 100 Ω (In the monitor focus function, it can also be set at ±5 V, 0 to 5 V, etc.) |
||
| Temperature characteristics | ±0.2 % F.S./℃ (Note 3) | ||
| Settable average sampling rate (Note 4) | 1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1,024 / 2,048 / 4,096 | ||
| Judgment outputs (HIGH, PASS, LOW) |
NPN open-collector transistor ・Maximum sink current: 50 mA ・Applied voltage: 30 V DC or less (between judgment output and 0 V) ・Residual voltage: 1.2 V or less (at 50 mA sink current) |
PNP open-collector transistor ・Maximum source current: 50 mA ・Applied voltage: 30 V DC or less (between judgment output and +V) ・Residual voltage: 2 V or less (at 50 mA source current) |
|
| Utilization category | DC-12 or DC-13 | ||
| Number of outputs | HIGH / PASS / LOW 3 values output | ||
| Output operation | HIGH: ON when measured value > HIGH threshold value PASS: ON when HIGH threshold value ≥ measured value ≥ LOW threshold value LOW: ON when LOW threshold value > measured value |
||
| Short-circuit protection | Incorporated | ||
| Laser OFF input | 0 V connection: Laser emission halt Open: Laser emission ・Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
+V connection: Laser emission halt Open: Laser emission ・Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
|
| Zero reset input | 0 V connection: Zero reset operates Open: Zero reset ineffective ・Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
+V connection: Zero reset operates Open: Zero reset ineffective ・Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
|
| Timing input | 0 V connection: Effective Open: Ineffective ・Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
+V connection: Effective Open: Ineffective ・Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
|
| Reset input | 0 V connection: Effective Open: Ineffective ・Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
+V connection: Effective Open: Ineffective ・Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
|
| Indicators | Laser emitting (LD ON) | Green LED (lights up during laser emission) | |
| Judgment outputs | HIGH: Orange LED (lights up when measured value > HIGH threshold value) PASS: Green LED (lights up when HIGH threshold value ≥ measured value ≥ LOW threshold value) LOW: Yellow LED (lights up when LOW threshold value > measured value) |
||
| Enable (ENABLE) | Green LED (lights up during normal operation) | ||
| Zero reset (ZERO) | Green LED (lights up when the zero reset function is enabled) |
||
| Main digital display | 5 digit red LED display (RUN mode: Either the measured value (mm) or the hold value will be displayed. Reverse mode: The display orientation will be reversed.) |
||
| Sub-digital display | 5 digit yellow LED display (RUN mode: Either the resolution or laser beam reception amount will be displayed. THR mode: The threshold value will be displayed., Reverse mode: The display orientation will be reversed.) |
||
| Main functions | ・Measured value display ・Setting value, light amount value resolution display ・Standard received light setting ・Automatic scaling ・Scaling ・Display reverse ・ECO display ・Display digits limitation ・Sample hold ・Peak hold ・Bottom hold ・Peak to peak hold ・Self peak hold ・Self bottom hold ・Zero reset ・Initial reset ・ON-delay timer ・OFF-delay timer ・ONE SHOT timer ・Differentiation ・Sensitivity selection ・Threshold value direct setting ・Positioning teaching ・2-level teaching ・Automatic teaching ・Hysteresis width variablily ・Monitor focus ・Non-measuring time setting ・(A-B) calculation (Note 5) ・(A + B) calculation (Note 5) ・Mutual interference prevention (Note 5) ・Laser deterioration detection ・Key lock ・Zero reset memory |
||
| Pollution degree | 3 (industrial environment) | ||
| Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation), Storage: -25 to +65 ℃ -13 to +149 ℉ |
||
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
| EMC | EN 61000-6-2, EN 61000-6-4 | ||
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||
| Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | ||
| Vibration resistance | 10 to 150 Hz frequency, 0.7 mm 0.028 in amplitude in X, Y and Z directions for 80 min. | ||
| Shock resistance | 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions for three times each | ||
| Material | Enclosure: Polybutylene terephthalate, Transparent cover: Polycarbonate | ||
| I/O cable | 0.09 mm2 10-core composite cable, 2 m 6.562 ft long | ||
| I/O cable extension | Extension up to total 10 m 32.808 ft is possible, with 0.09 mm2 or more, cable. (Note 6) |
||
| Weight | Net weight: 140 g approx. | ||
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Switching between current and voltage is accomplished by a switch on the bottom of the controller.
3) These are the temperature characteristics of the linear output when the sensor head is connected.
4) The judgment output and linear output and linear output response time is calculated by (Measuring cycle) x (Set average sampling rate + 1).
5) The calculation unit is necessary.
6) If the extension cable is longer than 10 m 32.808 ft, then it will not qualify for CE marking.





