| Discontinued Products | Direct Replacement | Recommended Subsitution | Description | |||
| Series | Model | Series | Model | Series | Model | |
GA-14/15 with GH_S Sensor heads | GA-14 | GA-311 | Substitution model does not incorporate the disconnection alarm indicator/a quick-connection cable(CN-73-C*) is needed. | |||
| GA-14-C5 | GA-311 | Substitution model does not incorporate the disconnection alarm indicator/a quick-connection cable(CN-73-C*) is needed. | ||||
| GA-14J | GA-311 | Substitution model does not incorporate the disconnection alarm indicator/a quick-connection cable(CN-73-C*) is needed. | ||||
| GA-15 | GA-311 Series | GA-311 | Substitution model does not incorporate the disconnection alarm indicator/a quick-connection cable(CN-73-C*) is needed. | |||
| GA-15-C5 | with GH-_SE | GA-311 | Substitution model does not incorporate the disconnection alarm indicator/a quick-connection cable(CN-73-C*) is needed. | |||
| GA-15J | Sensor Heads | GA-311 | Substitution model does not incorporate the disconnection alarm indicator/a quick-connection cable(CN-73-C*) is needed. | |||
| GH-2S | GH-2SE | Substitution model is a plug-in connector type. | ||||
| GH-3S | GH-3SE | Substitution model is a plug-in connector type. | ||||
| GH-5S | GH-5SE | Substitution model is a plug-in connector type. | ||||
| GH-8S | GH-8SE | Substitution model is a plug-in connector type. | ||||
| GH-F8S | GH-F8SE | Substitution model is a plug-in connector type. | ||||
GX series | GX-12M | GX-N series | GX-N12M | |||
| GX-12MB | GX-N12MB | |||||
| GX-12ML | GX-N12ML | 1.5 times longer sensing distance. | ||||
| GX-12MLB | GX-N12MLB | Non-shielded type is available. | ||||
| GX-18M | GX-N18M | Thicker enclosure. | ||||
| GX-18MB | GX-N18MB | Supply voltage changed (conventional: from 10 to 30V | ||||
| GX-18ML | GX-N18ML | new: from 12 to 24VDC) | ||||
| GX-18MLB | GX-N18MLB | |||||
| GX-30M | GX-N30M | |||||
| GX-30MB | GX-N30MB | |||||
GXL series | GXL-12F | GXL-N series | GXL-N12F | Supply voltage changed (conventional: from 5 to 24V | ||
| GXL-12FI | GXL-N12FI | new: from 12 to 24VDC) | ||||
| GXL-12F-P | GXL-N12F-P | Models with "N" are equipped with operation indicator. | ||||
| GXL-12FI-P | GXL-N12FI-P | These models, with normally open NPN output, are also available as 5V supply voltage type. | ||||
| GXL-12FT | GXL-N12FT | ("-5" was added to the end of model numbers.) | ||||
| GXL-12FTI | GXL-N12FTI | Model no. of an optional connector changed from CN-03 to CN-13. | ||||
| GXL-12FT-P | GXL-N12FT-P | No compatibility of a connector. | ||||
| GXL-12FTI-P | GXL-N12FTI-P | |||||
| GS3 series | No Direct Replacement or Recommended Subsitution | Metal-free inductive proximity sensor | ||||
| GS4 series | Metal-select inductive proximity sensor | |||||
| GSA series | Amplifier-separated analog-output inductive proximity sensor | |||||