KW Power Meters Specifications

Power Meters KW

Specifications for this product appear below.

Measurement items

Item KW4M KW7M KW8M
Instantaneous electrical power 0.00 to 9999.99KW Active power: 0.00 to 9999999.9KWh
Reactive Power: 0.00 to 9999999.9Kvarh
Apparent Power:  0.00 to 9999999.9KVAh
Integrated electrical power 0.00 to 9999.99kWh to 10.00MWh to 9999.99MWh
9-digit display: 0.00 to 9999999.99kWh
0.00 to 999999.99 to 1000000.0 to 9999999.9KWh Active power: 0.00 to 999999.99KWh
Reactive Power: –99999.99 to 0.00 to 999999.99Kvarh
Apparent Power:  0.00 to 999999.99KVAh
Current MEWTOCOL type:  L1(CT1),L2(CT2)phase current: 0.0 to 999.9A
Modbus type       :  L1(CT1),L2(CT2)phase current:  0.0 to 6000.0A
L1(CT1)phase current: 0.0 to 999.9 to 1000 to 6000A
L2(CT2)phase current: 0.0 to 999.9 to 1000 to 6000A
CT1:0.0 to 6000A
CT2:0.0 to 6000A
CT3:0.0 to 6000A
Voltage Voltage between 1-2: 0.0 to 9999.9V
Voltage between 2-3: 0.0 to 9999.9V
Voltage between 1-2: 0.0 to 999.9 to 1000 to 9999A
Voltage between 2-3: 0.0 to 999.9 to 1000 to 9999A
Voltage between P1 and P0: 0.0 to 9999V
Voltage between P2 and P0: 0.0 to 9999V
Voltage between P3 and P0: 0.0 to 9999V
Electricity charge *1 Yen 0 to 999999JPY 0.00 to 99999999
Dollars 0 to 9999.99$
Euros 0 to 9999.99EUR
Yuan 0 to 9999.99CNY
Power Factor Display - - 0.00 to 1.00 (Distiguishes if ahead (LEAD) or behind (LAG).)
Communication - - –1.00 to 0.00 to 1.00 (Within range of phase angle θ = –90 to 0 to +90°)
Frequency     47.5 to 63.0
Hour meter ON time 0.0 to 99999.9 h(Hour)   0.0 to 99999.9 h(Hour)
OFF time 0.0 to 99999.9 h(Hour)   0.0 to 99999.9 h(Hour)
Pulse input 0 to 999999 Counts - 0 to 99999999 Counts

^ Back to top

Main unit

Item KW4M KW7M KW8M
Rated operating voltage 100-120/200-240V AC 100 to 240V AC
Rated frequency 50/60 Hz common 50/60Hz
Rated power consumption 8VA 6 VA 8VA
Allowable operating voltage range 85 to 132/170 to 264V AC (85% to 110% of rated operating voltage) 85 to 264V AC (85% to 110% of rated operating voltage)
Allowable power off time 10ms
Ambient temperature -10°C to +50°C/+14°F to +122°F (Storage temperature: -25°C to +70°C/ - 13°F to 158°F)
Ambient humidity 30 to 85%RH (at 20°C non-condensing)
Display method With Backlight 6-digit, 7-segment LCD for settings and 4-digit, 16-segment LCD for modes. Upper display: green, Lower display: amber 7-segment LED 8-digit, 7-segment LED
Power failure memory method EEP-ROM (Over 100,000 overwrites)
Protective construction IP66 (front panel with rubber gasket)
Note: Waterproofing (IP66)will be lost in continuous (permanently attached)installations.
- -
Weight For 11-pin type: approx. 130 g,
For Screw terminal type: approx. 140 g
approx. 100 g AKW8111: approx.235g
AKW8111H: approx.250g

^ Back to top

Input specs

Item KW4M KW7M KW8M
Input voltage Rating Single-phase two-wire : 100-120/200-240V AC(common)
Single-phase three-wire : 100-120V AC
Three-phase three-wire : 200-240V AC
Single-phase two-wire: 0 to 440V AC (Line voltage)
Single-phase three-wire: 0 to 220V AC (Phase voltage)
Three-phase three-wire: 0 to 440V AC (Line voltage)
Three-phase four-wire: 0 to 254V AC (Phase voltage)
Allowable measuring voltage 85% to 110% of rated operating voltage
Single-phase two-wire : 85-132/170-264V AC(common)
Single-phase three-wire : 85-132V AC
Three-phase three-wire : 170-264V AC
VT ratio 1.00 to 99.99 [External voltage transformer (VT) is required.]
※Voltage transformer (VT) is required when you measure a load with voltage over 200V system.
※Secondary current rating of commercial VT is 110V.
1.00 to 99.99 (Set with setting mode)
*Voltage transformer (VT) is required when you measure a load with voltage over 440V system. (Secondary side: 110V)
Max. displayed voltage 9999.9 V 9999 V  
Input current Primary side rating <In case using dedicated CT>
・5A/50A/100A/250A/400A (Select with setting mode)
<In case using 5A CT with secondary rating 5A>
・1~999.9A (Set with setting mode) (MEWTOCOL type)
・1~4000A (Set with setting mode) (MODBUS type)
※Use a commercial CT with secondary side current of 5A when measuring 400A or more.
※Accuracy coverage:10~100% of rated current of CT
• 5A/50A/100A/250A/400A (In case using dedicated CT.) (Select with setting mode)
• 1 to 4000A (Set with setting mode)
*Use a commercial CT with secondary side current of 5A when measure 400A or more.
*Accuracy coverage: 10 to 100% of rated current of CT
CT ratio ・1~999 (Set with setting mode) (MEWTOCOL type)
・1~4000 (Set with setting mode) (MODBUS type)
※In case measuring CT of secondary rated current 5A.
1 to 4000/5 A (Can be set in setting mode.) (Supported when dedicated CT used in 2-step configuration.)  
Max. displayed current ・ 999.9A (MEWTOCOL type)
・6000.0A (MODBUS type)
6000 A (When 400 A or higher, use commercial CT with 5 A rated secondary current.)  
Accuracy Basic accuracy    Instantaneous electric power, Integrated electrical energy
Voltage, Current, Electricity charge
Instantaneous electrical power, Integrated electrical energy, Voltage, Current and Electricity charge  
±2.5% F.S. ±1digit
(at 20℃, rated input, rated frequency, power-factor 1)
※Accuracy coverage:10~100% of rated current of CT
[±2.5% F.S. ±1 digit (at 20°C rated input, rated frequency, power factor: 1),
Guarantee accuracy range: 10 to 100% of a rated current of each CT]
 
Hour Meter -  
±0.01%±1digit (at 20℃)
(In case power on start or current energizing,±0.01%+1s±1 digit)
-  
  Temperature characteristics ±1.5% F.S. /10℃ ±1digit
(Range of –10 to 50℃ based on 20℃ for rated input power-factor 1)
±1.5% F.S./10°C ±1 digit (for -10 to 50°C range, rated input and power factor: 1)  
  Frequency characteristics ±1.5% F.S.±1 digit
(Frequency change±5% based on rated frequency, for rated input power-factor 1)
±1.5% F.S. ±1 digit (for ±5% frequency change, rated input and power factor: 1)  

^ Back to top

Communications

Item KW4M KW7M
Interface Conforming to RS485
Protocol MEWTOCOL/Modbus(RTU)(Depending on part number.)
Number of connected units Max. 99 units
Transmission distance Max. 1,200m

^ Back to top

Pulse input

Item KW4M KW7M
Input mode Addition (fixed) -
Max. counting speed 2 kHz/30 Hz (selectable by mode) -
Pulse input Min. input signal width: 0.25 ms (when 2 kHz selected)/16.7 ms (when 30 Hz selected) ON : OFF ratio = 1 : 1 -
Input signal Contact/No contact (open collector) -
· Impedance when shorted: 1kohm -
· Residual voltage when shorted: Max. 2 V -
· Impedance when open: 100kohm -
Output mode HOLD (over count) -
Number of digits 6 digits display (0 to 999999)(selectable by mode) -

^ Back to top

Pulse output (transistor output)

Item KW4M KW7M
Number of output points 1 point -
Insulation method Optical coupler -
Output type Open collector -
Output capacity 100mA 30V DC -
Pulse width Approx. 100ms -
ON state voltage drop 1.5V or less -
OFF state leakage current 100 µA or less -
Pulse output unit *2 When measuring power 0.001/0.01/0.1/1/10/100 kWh/Alarm (selectable by mode) -
When measuring pulse input HOLD (over count) -

Notes
* Power and pulse output are not possible at the same time

^ Back to top

 