FP2 PLC Programmable Controls Specifications
Specifications for this product appear below.
| Item | Description | |||
|---|---|---|---|---|
| FP2 | FP2SH | |||
| Power supply / I/O Specifications | Power supply | 100 V to 120 V AC / 200 V to 240 V AC/100 V to 240 V AC, 24 V DC (varies with different models) | ||
| Input | 12 V to 24 V DC, 24 V DC ±common | |||
| Output | Relay 2 A to 5 A / Transistor 0.1 A to 0.5 A (varies with different models) | |||
| Performance Specifications | Number of I/O points | Up to 768 points | ||
| Expansion | Up to 1 backplane Max. number of I/O points: 1600 Remote I/O: 2048 points | Up to 1 backplane Max. number of I/O points: 1,600 Remote I/O: 8192 points | ||
| Operation speed | 0.35µs/step (Basic instuction) | 0.03µs/step (Basic instuction) | ||
| Built-in memory | RAM (ROM is optional) | RAM (ROM/Small PC card is optional) | ||
| Memory capacity | Approx.16k steps | Approx. 60k steps/Approx. 120k steps (varies with defferent models) | ||
| Operation memory | Internal relay | 4048 points | 14192 points | |
| Timer/Counter(T/C) | 1024 points in total | 3072 points in total | ||
| Data register | 6000 words | 10240 words | ||
| File register | 0 to 14333 words (when expanding: 0 to 30717 words) | 32765 words × 3 banks | ||
| Special Functions | Analog I/O | Available by adding analog input and analog output units. | ||
| High speed counter | Available by adding high-speed counter unit. (Max. 200 kHz) | |||
| Pulse output | Positioning unit 2-axis Positioning unit 4-axis | |||
| RS232C | RS232C port is standard equipped on CPU unit. Expandable by adding C.C.U. and serial data unit. | |||
| Interrupt input | Available by adding high-speed counter unit or pulse I/O unit. | |||
| Special Network Functions | Remote I/O | S-LINK, MEWNET-F | ||
| PLC Link | MEWNET-W (Wire) MEWNET-W2 (Wire) | |||
| Computer Link | Linkable by using tool port or COM. port on CPU unit. Also available by adding C.C.U. | |||
| Modem connection | Available | |||
| Other Built-in Functions | Program block-edit during RUN | Available | ||
| Constant scan | Available | |||
| Clock/Calendar function | Can be used with the addition of the calendar function option. | Built-in type | ||