LC4H Counters Specifications
Specifications for this product appear below.
LC-4H / LC-4H-L Counters
| Type | Ralay output type | Transistor output type | ||||
|---|---|---|---|---|---|---|
| Item | AC type | DC type | AC type, AC/DC type | DC type | ||
| Rating | Rated operating voltage | 100 to 240 V AC, 24 V AC | 12 to 24 V DC | 100 to 240 V AC, 24 V AC, 24 V AC/DC | 12 to 24 V DC | |
| Rated frequency | 50/60 Hz common | - | 50/60 Hz common | - | ||
| Rated power consumption | Max. 10 V A | Max. 3 W | Max. 10 V A | Max. 3 W | ||
| Rated control capacity | 5 A 250 V AC (resistive load) | 100 mA 30 V DC | ||||
| Input mode | Addition (UP)/Subtraction (DOWN)/Direction (DIR)/Individuality (IND)/Phase (PHASE) 5 modes selectable by DIP switch |
|||||
| Max. counting speed | 30 Hz/5 kHz (selectable by DIP switch) | |||||
| Counting input (Input 1, 2) | Min. input signal width: 16.7 ms at 30 Hz/0.1 ms at 5 kHz, ON time: OFF time = 1:1 | |||||
| Reset input | Min. input signal width: 1 ms, 20 ms (selected by DIP switch) | |||||
| Lock input | Min. input signal width: 20 ms | |||||
| Input signal | Contact or Open collector input/Input impedance: 1 kΩ or less, Input residual voltage: 2 V or less, Open impedance: 100 kΩ or more, Max. energized voltage: 40 V DC |
|||||
| Output mode | HOLD-A/HOLD-B/HOLD-C/SHOT-A/SHOT-B/SHOT-C/SHOT-D (7 modes selectable by DIP switch) | |||||
| One shot output time | Approx. 1 s | |||||
| Indication | 7-segment LCD, Counter value (backlight red LED), Setting value (backlight yellow LED) | |||||
| Digit | 4-digit display type –999 to 9999 (–3 digits to +4 digits) (0 to 9999 for setting) 6-digit display type –99999 to 999999 (–5 digits to 6 digits) (0 to 999999 for setting) |
|||||
| Memory | EEP-ROM (Overwriting times: 105 ope. or more) | |||||
| Contact | Contact arrangement | 1 Form C | 1 Form A (Open collector) | |||
| Initial contact resistance | 100 mΩ (at 1 A 6 V DC) | - | ||||
| Contact material | Ag alloy/Au flush | - | ||||
| Life | Mechanical (contact) | 2×107 ope. (Except for switch operation parts) | - | |||
| Electrical (contact) | 105 ope. (At rated control voltage) | 107 ope. (At rated control voltage) | ||||
| Electrical | Allowable operating voltage range | 85 to 110 % of rated operating voltage | ||||
| Break down voltage (Initial value) |
Between live and dead metal parts: 2,000 Vrms for 1 min (11-pin type) Between input and output: 2,000 Vrms for 1 min Between open contacts: 1,000 Vrms for 1 min |
Between live and dead metal parts: 2,000 Vrms for 1 min (11-pin type) Between input and output: 2,000 V AC for 1 min |
||||
| Insulation resistance (At 500 V DC) (Initial value) | Between live and dead metal parts: Min. 100 MΩ (11-pin type) Between input and output: Min. 100 MΩ Between open contact: Min. 100 MΩ |
Between live and dead metal parts: Min. 100 MΩ (11-pin type) Between input and output: Min. 100 MΩ |
||||
| Temperature rise | Max. 65°C (under the flow of nominal operating current at nominal voltage) | - | ||||
| Mechanical | Vibration resistance | Functional | 10 to 55 Hz (1 cycle/min), single amplitude: 0.35 mm (10 min on 3 axes) | |||
| Destructive | 10 to 55 Hz (1 cycle/min), single amplitude: 0.75 mm (1 h on 3 axes) | |||||
| Shock resistance | Functional | Min. 98 m 321.522 ft./s2 (4 times on 3 axes) | ||||
| Destructive | Min. 294 m 964.567 ft./s2 (5 times on 3 axes) | |||||
| Operating conditions | Ambient temperature | –10°C to 55°C/ +14°F to +131°F | ||||
| Ambient humidity | Max. 85 % RH (non-condensing) | |||||
| Air pressure | 860 to 1,060 h Pa | |||||
| Ripple rate | - | 20 % or less | - | 20 % or less | ||
| Connection | 8-pin/11-pin/screw terminal | |||||
| Protective construction | IP66 (front panel with a rubber gasket) | |||||
LC-4H-S Counters
| Type | Ralay output type | Transistor output type | |||
|---|---|---|---|---|---|
| Item | AC type | DC/AC type | DC/AC type | ||
| Rating | Rated operating voltage | 100 to 240 V | 12 to 24 V DC/24 V AC | 12 to 24 V DC/24 V AC | |
| Rated frequency | 50/60 Hz common | ||||
| Rated power consumption | Max. 10 V A | Max. 3 W | |||
| Rated control capacity | 5 A 250 V AC (resistive load) | 100 mA, 30 V DC | |||
| Input mode | Addition (UP)/Subtraction (DOWN)/Direction (DIR)/Individuality (IND)/Phase (PHASE) 5 modes selectable by DIP switches |
||||
| Max. counting speed | 30 Hz, 5 kHz (selectable by DIP switches) | ||||
| Counting input (input 1, input 2) |
16.7 ms at 30 Hz/0.1 ms at 5 kHz ON time: OFF time = 1:1 | ||||
| Reset input | Min. input signal width: 1 ms, 20 ms (selected by DIP switches) | ||||
| Lock input | Min. input signal width: 20 ms | ||||
| Input signal | Contact, Open collector input/DC two-wire system sensor Input impedance: 1 kΩ or less, Input residual voltage: 2 V or less, Open impedance: 100 kΩ or less, Max. energized voltage: 40 V DC |
||||
| Output mode | HOLD-A, HOLD-B, HOLD-C, SHOT-A, SHOT-B, SHOT-C, SHOT-D, 7 modes selectable by DIP switches | ||||
| One shot output time | 1 s, 0.5s, 0.2s, 0.1s, 0.05, 0.01s | ||||
| Indication | 7-segment LCD, Counter value (backlight red LED), Setting value (backlight yellow LED) | ||||
| Digit | 4-digit display type –999 to 9999 (0 to 9999 for setting) 6-digit display type –99999 to 999999 (0 to 999999 for setting) |
||||
| Decimal point | Can be set to three digits | ||||
| Pre-scaling | 0.001 to 9.999 (4-digit type), 0.001 to 99.999 (6-digit type) | ||||
| Memory | EEP-ROM (Overwriting times: 105 ope. or more) | ||||
| Power for senser | 12 V DC (±10%) 100 mA Max. | - | |||
| Contact | Contact arrangement | 1 Form C | 1 Form A (Open collector) | ||
| Initial contact resistance | 100 mΩ (at 1 A 6 V DC) | - | |||
| Contact material | Ag alloy/Au flush | - | |||
| Life | Mechanical (contact) |
2×107 ope. (Except for switch operation parts) | - | ||
| Electrical (contact) |
105 ope. (At rated control voltage) | 107 ope. (At rated control voltage) | |||
| Electrical | Operating voltage range | 85 to 264 V AC | 10.8 to 26.4 V DC, 20.4 to 26.4 V AC | ||
| Initial withstand voltage | Between live and dead metal parts: 2,000 Vrms for 1 min (pin type) Between input and output: 2,000 Vrms for 1 min |
||||
| Initial insulation resistance (At 500 V DC) |
Between live and dead metal parts: Min. 100 MΩ (pin type) Between input and output: Min. 100 MΩ |
||||
| Temperature rise | Max. 65°C (under the flow of nominal operating current at nominal voltage) | ||||
| Mechanical | Vibration resistance | Functional | 10 to 55 Hz (1 cycle/min), single amplitude: 0.35 mm (10 min on 3 axes) | ||
| Destructive | 10 to 55 Hz (1 cycle/min), single amplitude: 0.75 mm (1 h on 3 axes) | ||||
| Shock resistance | Functional | Min. 98 m/s2 (4 times on 3 axes) | |||
| Destructive | Min. 294 m/s2 (5 times on 3 axes) | ||||
| Operating conditions | Ambient temperature | –10°C to 55°C/ +14°F to +131°F | |||
| Ambient humidity | Max. 85 % RH (non-condensing) | ||||
| Air pressure | 860 to 1,060 h Pa | ||||
| Connection | 11-pin/screw terminal | ||||
| Protective construction | IP66 (front panel with a rubber gasket) | ||||
LC-4H-W Counters
| Item | Ralay output type | Transistor output type | ||||
|---|---|---|---|---|---|---|
| AC type | DC type | AC type | DC type | |||
| Rating | Rated operating voltage | 100 to 240 V AC 24 V AC | 12 to 24 V DC | 100 to 240 V AC 24 V AC | 12 to 24 V DC | |
| Rated frequency | 50/60 Hz common | - |
50/60 Hz common | - |
||
| Power consumption | Max. 10 V A | Max. 3 W | Max. 10 V A | Max. 3 W | ||
| Rated control capacity | 3 A, 250 V AC (resistive load) | 100 mA, 30 V DC | ||||
| Input mode | Addition (UP)/Subtraction (DOWN)/Direction (DIR)/Individuality (IND)/Phase (PHASE) 5 modes selectable by DIP switch | |||||
| Counting speed | 30 Hz(cps)/5 KHz(cps) (selectable by DIP switch) | |||||
| Counting input (Input 1, 2) | Min. input signal width: 16.7 ms at 30 Hz(cps)/0.1 ms at 5 KHz(cps) ON time: OFF time = 1:1 | |||||
| Reset input method | Min. input signal width: 1 ms, 20 ms (selected by DIP switch) | |||||
| Input signal | Contact or Open collector input/Input impedance: 1 kΩ or less, Input residual voltage: 2 V or less, Open impedance: 100 kΩ or less, Max. energized voltage: 40 V DC | |||||
| Output mode | Output 1. HOLD-B, C, D SHOT-A (4 modes) Output 2. HOLD-A, B, C SHOT-A, B, C, D (8 modes) (selectable by DIP switch) |
|||||
| One shot output time | Approx. 1 s | |||||
| Indication | 7-segment LCD, Counter value (backlight red LED), Setting value (backlight yellow LED) | |||||
| Digit | -99999 to 999999 (-5 digits to 6 digits) (0 to 999999 for setting) | |||||
| Memory | EEP-ROM (Overwriting times: 105ope. or more) | |||||
| Contact | Contact arrangement | 1 Form A + 1 Form A | 1 Form A + 1 Form A (Open collector) | |||
| Contact resistance (Intial value) | 100 mΩ (at 1 A 6 V DC) | - |
||||
| Contact material | Ag alloy/Au flush | - |
||||
| Life | Mechanical(contact) | Min. 2.0×107ope. | - |
|||
| Electrical(contact) | Min. 1.0×105ope. (At rated control voltage) | Min. 1.0×107ope. (At rated control voltage) | ||||
| Electrical | Allowable operating voltage range | 85 to 110 % of rated operating voltage | ||||
| Break down voltage (Initial value) |
Between live and dead metal parts: 2, 000 Vrms for 1 min (pin type) Between input and output: 2, 000 Vrms for 1 min Between open contacts: 1, 000 Vrms for 1 min |
Between live and dead metal parts: 2, 000 Vrms for 1 min Between input and output: 2, 000 V AC for 1 min |
||||
| Insulation resistance (At 500 V DC) (Initial value) | Between live and dead metal parts: Min. 100 MΩ (pin type) Between input and output: Min. 100 MΩ Between open contact: Min. 100 MΩ |
Between live and dead metal parts: Min. 100 MΩ (pin type) Between input and output: Min. 100 MΩ |
||||
| Temperature rise | Max. 65°C (under the flow of nominal operating current at nominal voltage) |
- |
||||
| Mechanical | Vibration resistance | Functional | 10 to 55 Hz (1 cycle/min), single amplitude: 0.35 mm .014 inch (10 min on 3 axes) | |||
| Destructive | 10 to 55 Hz (1 cycle/min), single amplitude: 0.75 mm .030 inch (1 h on 3 axes) | |||||
| Shock resistance | Functional | Min. 98 m/s2 321.522 ft./s2(4 times on 3 axes) | ||||
| Destructive | Min. 294 m/s2 964.567 ft./s2(5 times on 3 axes) | |||||
| Operating conditions | Ambient temperature | -10°C to 55°C/ +14 ° F to +131 ° F | ||||
| Ambient humidity | Max. 85 % RH (non-condensing) | |||||
| Air pressure | 860 to 1, 060 h Pa | |||||
| Ripple rate | - |
20 % or less | - |
20 % or less | ||
| Connection | 11-pin/screw terminal | |||||
| Protective construction | IP66 (front panel with a rubber gasket) | |||||